2.3 Controls, sensors

RB-
RB-ZF4
ZF4
room air control
for
● standard unit
● comfort unit
Optional for
● bypass unit
RB-
RB-D1-ZF4
D1-
room air control
ZF4
for
● bypass unit
Optional for
● standard unit
● comfort unit
SKD CO
sensor
2
(optional)
EAQ
Air quality
10/2
sensor (VOC)
RFS
Humidity
control
(optional)

2.4 Intended use

● The RB 170 is used as a ventilation unit
with heat recovery system that provides
controlled ventilation of apartments, offices
or comparable rooms.
● The ventilation unit is only intended for
domestic use and similar purposes.
● The ventilation unit is only intended for
permanent installation in buildings. It may
only be fitted on walls with sufficient load-
bearing capacity.
● The RB 170 may only be used in line with
the calculations/designs carried out by the
engineering office.
With step switch and
filter monitoring.
Operating modes:
Humidity protection,
ventilation
level 1, 2 or 3.
Operation manual
(ventilation levels)
or with automatic
time program
P1 or P2.
Parameters:
switching times,
summer function,
bypass parameter.
Records the carbon
dioxide content
"CO
". The supply of
2
fresh air depends on
the level of CO
in the
2
room.
Controls the unit in
terms of air quality.
Records the relative
air humidity. The
supply of fresh air
depends on the level
of relative humidity in
the room.
2. Product information │ uk

2.5 Foreseeable cases of misuse

Aerex is not liable for damages caused by
use contrary to the intended purpose. Under
no circumstances should the unit be
used:
● during the building phase.
● in high levels of dust.
● close to flammable materials, liquids or
gases.
● to convey chemicals, aggressive gases
or vapours.
● In potentially explosive atmospheres.
● in swimming pools.
● to dry out new buildings.
● in combination with laboratory extractors.
● in combination with extractor hoods, that
are connected directly to the controlled
domestic ventilation exhaust air channel.
For energy-usage reasons, we
recommend using extractor hoods in
circulating air mode.

3. Safety instructions

3.1 General

● Ask your installer to familia-
rise you with the ventilation
unit and the room air control
once the installation is
complete.
● This fan unit can be used by
children aged 8 and above,
and by people with reduced
physical, sensory or mental
capabilities or by persons with
insufficient experience or
knowledge provided they
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Reco-boxx rb 170 rReco-boxx rb 170 clReco-boxx rb 170 cr

Table des Matières