uk │ 10. Technical data
10. Technical data
Housing dimensions
(W x H x D) in mm
● RB 170 standard unit
● RB 170 comfort unit
● RB 170 bypass unit
Material
Air connections
Condensation drain
Protection class
Degree of protection
G4 outside air filter:
Included with standard unit,
optional with comfort and
bypass unit
G4 exhaust air filter:
Included in all units
F7 pollen filter in comfort
and bypass unit
Permissible ambient
temperature
in installation room
Permissible moisture in
installation room (at 20 °C)
● Standard unit
● Comfort unit
● Bypass unit
Permitted outside air
temperature
Degree of heat
provision
38
595 x 820 x 375
595 x 820 x 375
595 x 820 x 435
Galvanised
sheet steel,
partly powder-
coated
Ø 125 mm
Sleeve with
28 mm diameter
lip seal,
28x19 mm
reducer for
3/4" hose
1
IP 00
RBG 170
air filter,
class G4
RBG 170
air filter,
class G4
RBF170,
pollen filter,
class F7
+10 ... +40 °C
50 % RH
70 % RH
70 % RH
-15 ... +60 °C
up to 94 %
Rated voltage
Mains frequency
Ventilation levels (factory
setting):
● Ventilation for humidity
protection (interval
operation)
● Reduced ventilation
● Nominal ventilation
● Intensive ventilation
Power consumption (unit)
at 100 Pa Counter
pressure per duct
● 60 m³/h
● 90 m³/h
● 120 m³/h
Weight
● Standard unit
● Comfort unit
● Bypass unit
11. Disposal
Packaging
Dispose of the packaging material in compli-
ance with the regulations valid in the country
where you live.
Air filter
Dispose of the air filter in compliance with the
regulations valid in the country where you
live.
Old units
The old unit must be dismantled by a specia-
list company and disposed of correctly.
Not in domestic waste. The unit
contains in part material that can be
recycled and in part substances that
should not end up as domestic waste.
230 V AC
50 Hz / 60 Hz
approx. 57 %
of reduced
ventilation
60 m³/h
90 m³/h
120 m³/h
24 W
35 W
50 W
38 kg
43 kg
47 kg