Description and use
The unit you have purchased is an axial centrifugal aspirator for
air expulsion in ventilation ducts. It is constructed of plastic self-
extinguishing material V0, is protected against sprays of water,
and is equipped with ball bearings, which guarantee at least
30,000 hours of mechanical operation and constant silence over
time.
IMPORTANT: The unit is able to develop 3 ventilation speeds,
as it is already equipped with suitable condensers. Operating
speed control is designated to pairing with an appropriate 3-speed
selector. For further information regarding the control device, see
the "Wiring diagrams" paragraph.
These appliances are designed for use
•
in
residential
properties.
Safety
Warning:
!
this symbol indicates that care must
be taken to avoid injury to the user
• Always use the product for the purpose it was intended, as
specified in this booklet.
• After removing the product from its packaging, ensure that it is
not damaged. If in doubt please contact a Vortice authorised
Technical Assistance Centre immediately. Never leave
packaging parts within reach of children or disabled persons.
• The use of any electric device requires compliance with a few
fundamental rules, including:
- Never touch it with wet or humid hands.
- Never touch it when barefoot.
- Do not allow use by unsupervised children or disabled persons.
• Do not use the unit in the presence of flammable substances or
vapours such as alcohol, insecticides, gasoline, etc.
This appliance can be used by children
•
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved.
Children shall not play with the
•
appliance.
Cleaning and user maintenance shall
•
not be made by children without
supervision.
Precautions must be taken to prevent
•
gas coming from the gas flue pipe or
from other fuel combustion units from
entering into the room.
and
commercial
Products installed without a protective
•
device for moving parts must be
installed at a height greater than 2.3 m
above the floor level.
Units equipped with manual reset
•
thermal breaker device
In order to avoid any danger of accidental
reset of the thermal breaker device, units
must not be powered by an external
switch device such as a timer, or must
not be connected to a circuit that is
regularly powered or disconnected from
power utilities.
Caution:
!
this symbol indicates that care must
be taken to avoid damaging the appliance
• Do not leave the device exposed to adverse weather conditions
(rain, sun, etc.).
• Do not rest objects on the device.
• Periodically check device conditions. If imperfections are noted,
do not use the unit and immediately contact a Vortice authorised
Technical Assistance Centre.
• Promptly contact a Vortice authorised Assistance Centre in the
event of unit malfunction and/or failure and request the use of
original Vortice spare parts for any repairs.
• If the unit falls or receives a strong blow, immediately have it
inspected at a Vortice authorised Technical Assistance Centre.
• Only connect the device to the mains supply/ electrical outlet if
plant/outlet capacity is suitable for its maximum power. If
otherwise, immediately seek assistance from a professionally
qualified person.
• Switch off the main switch on the system when: a) a malfunction
is detected, b) you decide to perform external cleaning
maintenance, c) when you decide not to use the device for
prolonged periods.
• It is essential to ensure that sufficient air re-enters the room, in
order to guarantee product operation. If a combustion-powered,
non air-tight device is installed in the room (water heater,
methane stove, etc.), please ensure that air re-entry also
guarantees the perfect combustion of said device.
• The unit cannot be used as an activator for water heaters,
stoves, etc. nor should it discharge into hot air ducts.
• Never cover the two intake grilles and the device return duct, to
ensure optimal air passage.
• The unit does not need to be connected to an
earthing system as it has been built in double isolation.
• The device must discharge in a single duct (used by this product
only).
• The product delivery point must always be
connected to a duct.
• Maximum room temperature for unit operation is 55°C.
• The electrical specifications correspond to the ones on the data
label A (fig.A).
An omnipolar switch with a contact
•
opening distance of 3 mm or higher
should be provided for installation,
9