Connect the Ice Maker (N8LXIM, and N7LXIM models)
The ice maker may be assembled to the refrigerators at the factory.
The refrigerator installer must connect a cold water supply line to the solenoid valve at the rear of the refrigerator. The following are
necessary to connect the ice maker:
- 1/4 in. OD copper tubing for the water supply line.
- 1/4 in. OD plastic tubing for the water supply line.
- 1/4 in. shut off valve in the water supply line. This should be easily accessible through the lower intake vent.
Connect the water supply line:
Install a 1/4 in. OD water supply line [43] from the water shut off valve of the vehicle to the solenoid water valve [44] at the rear of the
refrigerator (See Art 01014):
A brass compression nut [45], a brass sleeve [47], a plastic sleeve [46] , and a brass insert [47] are supplied and
NOTICE
attached to the rear of the refrigerator (See Art 01755).
- Put the compression nut and then the sleeve onto the water supply line [43].
- For copper tubing, use the brass sleeve [47].
- For plastic tubing, use the plastic sleeve [46].
- For plastic tubing with .040 in. wall thickness, also use the brass insert [47].
- Flush the water supply line until the water is clear.
- Put the tubing [43] into the water valve [44] until it is against the stop.
- Tighten the compression nut by hand (hard finger tight).
- Using two wrenches, tighten the compression nut 1 ½ to 2 turns.
- Open the water shut off valve of the vehicle.
- Examine the connections for leaks.
Installation Manual 16
OR
44
48
43
45
Art01014
45
46
47
43
ART 01755