Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42

Technical data

Function
AC current (50/60 Hz) True RMS
DC current
DC voltage
AC voltage (50/60 Hz) True RMS
Resistance
Function
A AC / VDC
V DC, V AC
Resistance, continuity test
Clamp opening
Capacitance measurement
Measurement range
Input resistance
Frequency range
AC current/voltage
PEAK hold
MAX/MIN hold
Operating temperature
Storage temperature
Humidity
Height above mean sea level
Overvoltage category
Power supply
Dimensions
Weight
Test standards
Subject to technical alterations. 07.2010.
20
GB
Range
Precision
200.0 AAC
± (2.5% ± 8 digits)
200.0 ADC
± (2.0% ± 5 digits)
600.0 VDC
± (1.0% ± 2 digits)
600.0 VAC
± (1.5% ± 8 digits)
999.9
± (1.5% ± 8 digits)
Max. input
200A (PEAK 282, 8A)
600V DC/AC
600V DC/AC
approx. 17 mm
Response threshold <30 ,
Test current <0.5 mA
10 measurements/sec. for numme-
ric display & 40 measurements/sec.
for bar graph display (DCA, DCV,
resistance measuring)
1.0 M (VDC, VAC)
50/400 Hz (True RMS)
measures peak current <10 ms
Measurement range <500 ms
-10°C ... 50°C
-30°C ... 60°C
non-condensing
90% (0°C ... 30°C);
75% (30°C ... 40°C);
45% (40°C ... 50°C)
relative humidity
Operation: 3,000 m;
Storage: 10,000 m
CAT III - 600V
2x 1.5 Type AAA, LR03, alkaline
164 x 65 x 32 mm
175 g
EN 61326; EN 61010-1;
EN 61010-2-031

Publicité

Table des Matières
loading

Table des Matières