Lenze Global Drive 8200 vector Instructions De Montage page 151

Convertisseur de fréquence
Masquer les pouces Voir aussi pour Global Drive 8200 vector:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Code
No.
Name
C0013
Deceleration
time main
uSEr
setpoint
C0014
Operating mode
v
C0015
V/f rated
frequency
uSEr
C0016
V
boost
min
uSEr
C0034
Range of
*
setpoint
v
selection
Standard I/O
uSEr
(X3/8)
EDK82EV222 DE/EN/FR 13.0
Possible settings
Lenze
Selection
5.00
0.00
2
2
V/f characteristic control V ~ f
(linear characteristic with constant V
boost)
3
V/f characteristic control V ~ f
(square−law characteristic with constant
V
boost)
min
4
Vector control
5
Sensorless torque control with speed
limitation
l
Torque setpoint via C0412/6
l
Speed limitation via setpoint 1
(NSET1−N1) if C0412/1 is assigned,
otherwise via maximum frequency
(C0011)
50.00
7.50
à
0.00
0
0
Unipolar voltage 0 ... 5 V / 0 ... 10 V
Current 0 ... 20 mA
1
Current 4 ... 20 mA
2
Bipolar voltage −10 V ... +10 V
3
Current 4 ... 20 mA open−circuit monitored TRIP Sd5 if I < 4 mA
Important codes for quick commissioning
{0.02 s}
1300.00
min
2
{0.02 Hz}
960.00
{0.01 %}
40.00
l
Commissioning
IMPORTANT
Reference: frequency change
C0011... 0 Hz
Additional setpoint ðC0221
l
l
Deceleration times that can be
activated via digital signals ð
C0103
l
Commissioning is possible
without identifying motor
parameters
l
Advantage of identification with
C0148:
– Improved smooth running
at low speeds
– V/f rated frequency (C0015)
and slip (C0021) are
calculated and saved. They
do not have to be entered
In the case of the first selection enter
the motor data and identify them
with C0148
Otherwise commissioning is not
possible
When C0014 = 5, C0019 must be set
= 0 (automatic DC injection brake is
deactivated)
l
C0015 is calculated and saved
during the motor parameter
identification with C0148.
l
The setting applies to all
permitted mains voltages
à
device−dependent
Setting applies to all permitted
mains voltages
Observe switch position of the
function module!
Reversal of rotation direction only
possible with a digital signal.
l
Minimum output frequency
(C0010) not effective
l
Individually adjust offset and
gain
Reversal of rotation direction only
possible with a digital signal.
7
151

Publicité

Table des Matières
loading

Table des Matières