WMBUS MODBUS MASTER - Guide utilisateur / User guide version V1.0.0
6. INSTALLATION ET UTILISATION
6.1. Correct positioning of the product
There are two key rules for optimising radio ranges.
•
The first one consists of positioning your product as high as possible.
•
The second one consists of limiting the number of obstacles in order to avoid excessive attenuation of the radio wave.
FR
Position: To the extent possible, install the transmitter at a minimum height of 1.50 m and do not attach it to the wall.
Obstacles: Ideally, the product must be 20 cm away from any obstacle and, if possible, near an opening (the closer the obstacle is, the more
the emitted power will be absorbed). All the materials encountered by a radio wave will attenuate it. Bear in mind that metal (metal cabinets,
beams, etc.) and concrete (reinforced concrete, partitions, walls, etc.) are the most critical materials for the propagation of radio waves.
6.2. Types of fastenings
EN
The product offers 3 fastening methods that enable numerous ways of positioning it depending on the environment where it has to be de-
ployed.
6.2.1 Tube or mast fastenings
As explained in section 4.1, the best radio
performance is achieved by positioning the
product as high as possible.
The fastening collar fastenings enable the
product to be fastened on a mast or tube
under completely safe conditions.
To optimise fastening onto a tube or mast,
we recommend you remove the Rail-DIN
locking/unlocking lever.
20 cm
Optimised positioning
Low radio range