12 Equipment Data

1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
1
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level to EN 12102
3.5
Sound pressure level at a distance of 1 m
3.6
Heating water flow with an internal pressure differential of m³/h / Pa
3.7
Brine throughput with an internal pressure differential
(heat source) of
3.8
Refrigerant / total filling weight
3.9
Lubricant / total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage / fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos 
5.4
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
7.4
Max. operating overpressure (heat source/heat sink)
1. For brine temperatures between -5 °C and 0 °C, flow temperature increasing from 65 °C to 70 °C.
2. This data indicates the size and capacity of the system to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and the
regulation, should also be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on the maintenance, start-up and operation
can be found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. B0/W35: Heat source temperature 0 °C and heating water flow temperature 35 °C.
3. Operation with 2 compressor
4. Operation with 1 compressors
5. Note that additional space is required for pipe connections, operation and maintenance.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
°C
°C
at B0 / W35
K
2
at B-5 / W55
kW / ---
kW / ---
2
at B0 / W45
kW / ---
kW / ---
2
at B0 / W50
kW / ---
kW / ---
2
at B0 / W35
kW / ---
kW / ---
dB(A)
m³/h / Pa
type / kg
type / litres
5
H x W x L mm
Inch
Inch
kg
V / A
2
B0 W35
kW
A
3
A / ---
W
7
bar
452234.66.08 · FD 9310
Monoethylene glycol
9.8
3
28.9 / 2.4
4
10.6 / 2.1
3
4
3
33.1 / 3.1
4
13.5 / 2.4
3
36.6 / 4.4
4
18.6 / 4.4
dB(A)
3.2 / 1100
11.0 / 11900
Polyolester (POE) / 6.5
1890 x 1350 x 775
G 1 1/2'' internal/external
G 2'' internal/external
8.36
21,9 / 0,55
SIH 40TE
SIH 40TE
IP 21
Indoors
up to 70±2
-5 to +25
25%
5.0
31.7 / 3.2
13.5 / 2.5
34.2 / 4.1
17.9 / 4.3
65
50
5.5 / 2900
8.8 / 7800
R134a / 8.0
502
400 / 50
8.35
84
21,9 / 0,55
65
6
Yes
2
Internal
3.0
EN-11