11
11 Technical Data
Device information for hot water heat pumps
Exhaust air ventilation hot water heat pump
Design
Nominal cylinder volume
Cylinder material
Nominal cylinder pressure
Dimensions height x width x depth
Weight (empty)
Electrical connection (plug-in - lead length approx. 2.7 m)
Remote control connection (min. 0.5 mm
Fuse
Refrigerant R 134a, total filling weight
Performance data
Exhaust air temperature range
Selectable water temperature (heat pump operation
Heating-up period from 15 °C to 60 °C
Fan level III
Power consumption supplementary electric heating
1
Mean power consumption
1
Mean heat output
COP (t) according to EN 255
Sound pressure level, at fan level III
Air flow: level I / II / III
External compression, level III
Maximum air duct connection length (total)
Air duct connection cross-section
Circulation pipe connection
Hot water outlet connection
Cold water inlet connection
1. Heating up of the nominal volume from 15°C to 45°C at L20 / F50 = exhaust air temperature 20 °C and exhaust air humidity 50% and fan level III
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on the exhaust air side)
E-10
(litre)
(bar)
(cm)
(kg)
2
suitable for supply voltage)
(A)
(kg)
(°C)
±1.5K
)
(°C)
at (L20 / F50)
(h)
(Watt)
at 45 °C
(Watt)
at 45 °C
(Watt)
at 45°C
2
(dB(A))
3
(m
/h)
(Pa)
(m)
(mm)
external thread
external thread
external thread
BWP 301L
Without additional internal heat exchanger
300
Enamelled steel according to DIN 4753
10
169.5 x 66 x 66
Approx. 110
230V ~ 50Hz
6-core
16
1.0
15 to 35
23 to 60
8.2
1500
570
1920
3,6
53
280, 330, 400
100
10
160
R 3/4"
R 1"
R 1"