Trouble Shooting

A
Danger!
Prior to all servicing:
– Switch machine OFF.
– Unplug power cable.
– Wait until the compressor has come
to a complete stop.
– Ensure the compressor and all air
tools and accessories connected to
it are relieved from pressure.
– Let the device and all air tools and
accessories cool down.
After all servicing:
– Check to see that all safety devices
are operational.
– Make sure that no tools or other
parts remain on or in the machine.
Compressor does not run:
No mains voltage.
– check cables, plug, outlet and
mains fuse.
Mains voltage too low.
– Use only extension cables with
sufficient lead cross section (see

"Technical Specifications").

When the machine is cold avoid
extension cables and relieve the
pressure in the pressure vessel.
Compressor was stopped by un-
plugging.
– Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
9.
Technical Specifications
Suction capacity
Free air delivery (volume flow rate)
Filling rate
Max. operating pressure
Max. bearing-/ operating temperature *)
Min. bearing-/ operating temperature *)
– First switch off the compressor
using the ON/OFF switch and al-
low to cool.
– Eliminate the cause of overheat-
ing.
– Switch the compressor back on.
Compressor runs but does not build
up sufficient pressure.
Condensation water drain on pres-
sure vessel leaky.
– Check the sealing of the outlet
screw(s); replace if necessary.
– Tighten the outlet screw(s) hand-
tight.
Check valve leaky.
– Have check valve serviced by
qualified service centre.
Air tool is not supplied with suffi-
cient pressure.
Pressure regulator not opened wide
enough.
– Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
– Check air hoses, replace defec-
tive parts if necessary.
Further work on the machine should
only be carried out by a qualified
electrician or the Service Centre in
your country.
7.

Repairs

A
Danger!
Repairs to electric tools must be carried
out by qualified electricians only!
ENGLISH
Electric tools in need of repair can be
send to the service centre in your coun-
try. Refer to the spare parts list for the
address.
Please attach a description of the fault
to the power tool.
8.

Environmetal Protection

A
Danger!
The condensation water from the pres-
sure vessel contains oil residues. Dis-
pose of the condensation water in an
environmentally-oriented manner at
one of the appropriate collection points!
A
Danger!
Dispose of the waste oil from the com-
pressor pump in an environmentally-ori-
ented manner at one of the appropriate
collection points!
The machine's packaging can be
100 % recycled.
Worn out machines and accessories
contain considerable amounts of valu-
able raw and plastic materials, which
can be recycled.
These instructions are printed on paper
produced with elemental chlorine-free
bleaching process.
l/min
l/min
l/min
bar
° C
° C
240
120
140
8
+ 40
+ 5
15

Publicité

Table des Matières
loading

Table des Matières