WARNINGS
Keep away from children or people with mental disabilities.
f
f
The device contains small pieces that can be swallowed.
In order to prevent any risk of strangulation, please keep
f
f
the electrodes wires away from children.
The device is meant for personal use. For reasons of hy-
f
f
giene, the electrode should only be used on one person.
Do not use the device by driving or by working on a
f
f
machine.
Do not use this electro stimulation unit in a damp environ-
f
f
ment, a bathroom, a sauna or close to electric machinery
connected to mains and earthed, or even piping earthed.
Use this device in a clean place (without dust nor dirt...).
f
f
Do not, under any circumstances, attempt to open or
f
f
repair the Multisportpro yourself! Only have repairs carried
out by the customer service department.
V. TECHNICAL SPECIFICATIONS
BELT
References : CTBB2MEAV2
Size (unisex) : from 34 to 60
Length of the unfolded belt :122 cm
Fabric : 35% sponge, 20% elastic
fabric, 15% polyester, 15% nylon, 10%
PVC + copper, 2% rubber, 3% non-
woven fabric
- USER MANUAL
TROUBLE SHOOTING
If your device doesn't work properly, do not use it and contact
your reseller.
PRECAUTIONS OF USE
Do not use the unit on your face.
f
f
Do not leave within reach of children.
f
f
Ask for advice from your physician:
if you have electronic or metallic implants (pins...),
f
f
in case of skin condition (wounds...).
f
f
CONTRA-INDICATIONS
Do not use SPORT-ELEC®:
On the heart area.
f
f
If you carry a pacemaker.
f
f
If you are pregnant.
f
f
During first 6 weeks after baby birth.
f
f
In case of neuromuscular diseases.
f
f
In case of hemorrhagic diseases.
f
f
On the face and skull.
f
f
RECOMMENDATIONS FOR MAINTAINING
AND CLEANING
Clean the unit with a tissue dampened with a disinfecting solu-
tion diluted with water at 1/10
ADHESIVE ELECTRODES
Reference : EASF110x71
Contact area : 67.5 x 47 mm (x2)
Estimated life expectancy : 40 uses
Class I medical device (Directive
93/42/CEE)
Adhesive, hydrophilic and hypoal-
lergenic electrodes
Please order new compatible
adhesive electrodes on www.sport-
elec.com.
.
th
AC ADAPTOR
Reference : MN-A403-E120
Input : 100-240V, 50/60Hz, 0.25 A max
Output : 5V
0.6A
The adapter is part of the equipment.
Only use the AC adaptor supplied
with the device.
Please replace this adaptor should it
fail (contact SPORT-ELEC® or order at
www.sport-elec.com).