Dust Extraction
Dust which occurs during your work is hazardous to health. That is why the
EOF 100.1 must be used with a vacuum cleaner, and a dust mask has to
be worn. The suitable Wet/Dry Vacuum Cleaner DSS 25 M / DSS 35 M iP
is available as accessory. It can directly be attached to the connection on
the dust hood.
Seting the milling depth
WARNING!
Before adjusting the milling depth and the protective cover,
disconnect the plug from the mains!
1
3
+
CAUTION!
Test the milling depth in advance on a test surface or start with a
smaller milling depth and then adjust the milling depth in steps to the
desired depth.
The required milling depth must be
set before a new surface is started.
For this, pull the locking bolt (1) in
upward direction (see arrow) and turn
the adjustment ring (3) until the milling
disk is flush with the protective cover (2).
Check on a level surface that the milling
elements and the protective cover have
full contact.
2
This means that the so-called "zero
point" has been reached.
-
Now you can set the desired milling
depth by turning the adjustment ring (3)
in direction "+".
One lock stage (drill hole) on the
adjustment ring corresponds to a milling
depth of 0.1 mm.
When the locking bolt (1) has entered
into one of the drill holes on the
adjustment ring (3), the protective cover
(2) can be turned separately in the
desired direction.
18
Instruction label on the machine