STUDER Innotec
2.3.3 Serial and parallel connection
3
Mounting and installing
3.1
Installation place
The location of the COMPACT must be driven by the following criteria:
Protection from unauthorized handling
Dry dust free room, no condensation
Never install directly over the battery and never in a cabinet together with the
batteries
Keep ventilation holes free
In mobile installations it is important to keep the vibrations down as low as
possible
3.2
Fixing
3.2.1 Fixing the COMPACT
Basically the COMPACT can be installed in any
desired location. Preferred is that the appliance be
wall mounted with battery cables downwards. The
COMPACT must be fixed directly on a flat, surface,
with four screws through the four holes (diameter
5.5mm) which are accessible from the outside. In
motor vehicles, the COMPACT must be fixed on a
flat plate itself fixed on vibrations reducing elements.
The COMPACT must not be fixed on a combustible
base, as the back of the casing can get hot and
reach up to 80 degree Celsius.
3.2.2 Protection cover IP-23
This cover IP23 (Order ref. CIP-23) can be easily
installed after the fixation of the COMPACT. For
that release a little the too screws down and more
the tow up. Then it's possible to pass the IP 23
cover between the COMPACT and the wall. The
cover must touch the screws. Lock on the four
screws, it's ready.
COMPACT V6.6
COMPACT
10/83