John Bean B800 Manuel D'utilisation page 96

Equilibreuse
Table des Matières

Publicité

6
3
8
7
96
4
4-10
5-47
5-48
5-49
Operation
5.17.3 Start optimisation or weight
minimisation
Procedure:
— Clamp the wheel or bare rim.
— Enter correct rim dimensions, or check existing
inputs for correctness.
— Close the wheel guard (if necessary press the
START key).
— Starting from the BALANCING Menu press key 6
Optimisation-Minimisation (Fig. 4-10).
The OPTIMISATION MENU screen "Step 1" is
displayed (Fig. 5-47).
If an optimisation/minimisation result has already been
saved, press key 7 (Fig. 5-48); in this way, the program
continues from the step where it was interrupted, with
the relative measurement values and settings, and the
optimisation/minimisation may continue.
At this point, you can choose whether to continue with
Optimisation (Key 8), or go to Minimisation (Key 4).
5.17.3.1 OPTIMISATION
— Clamp the rim only.
— Move the gauge arm into position on the rim, based
on the desired ALU.
— Perform a measuring run.
— In the BALANCING Menu press key 3 (Fig. 5-33).
The "Step 1" screen page appears (Fig. 5-48).
— Press the menu key 8 (Fig. 5-48).
The OPTIMISATION "Step 2" screen appears (Fig.
5-49).