4.6.4 Menu 04 – select language
With this selection it is possible to select the dialogue language
from those available entered in the menu, and namely:
-
ITALIAN
-
FRENCH
-
ENGLISH
-
GERMAN
4.6.5 Menu 05 – standby mode
With the selection of STANDBY mode ( ON selection ) the stove shuts down automatically after the room
temperature has remained above the SET value for a fixed time.
The next automatic relighting will be possible only when the room temperature falls below the set value entered in
the parameters table (default 2°C).
The manual commands from the control panel or remote control have priority over programming.
4.6.6 Menu 06 – buzzer
With this selection it is possible to activate/deactivate stove acoustic signalling.
4.6.7 Menu 07 – initial loading
The setting of INITIAL LOADING allows pellet preloading for a time equal to 90 sec. with the stove off or cold. It is
started with the button P1 and stopped with the button P4.
4.6.8 Menu 08 – stove status
With this selection it is possible to display the instantaneous stove status giving the operating status of the various
devices connected to it; various pages placed in succession are available for monitoring.
4.6.9 Menu 09 – settings by technician
This selection is reserved for the authorised technician of the COLA service centre.
Modification of the technical parameters of menu 09 must be done by authorised and competent
personnel; any changes made at random can cause serious damage for which COLA declines any
liability.
4.7 Hot air outlet flow adjustment
The SPRINT stove has a centrifugal fan for heat exchange with the combustion chamber, allowing the flow of hot air
to be conveyed frontally to the stove and/or at the top in ducting as described in par. 1.4; the hot air flow direction is
controlled manually by an internal valve with a lever and rod with knob.
The hot air flow depends on the choice of outlets and stove output; level 5 gives the maximum fan speed with
maximum flow of hot air.
The stove can convey the hot air flows entirely or partially to the front upper grille or the top grille and in the
connection of the ducting system by means of a valve controlled manually with a lever and rod; the rod, provided
with a knob, has 4 reference notches for selecting the hot air flow direction as shown in the figure.