4.6.1 Menu 01 – adjust fans
The speed of the air fans is authomatic and follows the maximum power programmed. If you want to decrease the
hot air flow it is possibile to set the maximum speed manually using the specific parameter in menu 01 and
choosing the value parameter from 1 up to 5: for example setting value parameter 3, the air fans will increase the air
flow speed authomatically without exceeding the value parameter 3 you programmed before.
As for ducted version the electrical connection is shown through led [ B ].
4.6.2 Menu 02 – set clock
The electronic control device has a lithium battery mod. CR2032 of 3 Volt inside. It allows the internal clock with
own autonomy; if the clock signal does not appear when the stove is off or when switching the stove again a series
of "0000" appears, it means it has to be substituted and you need to call one of our service point authorised for its
substitution.
4.6.3 Menu 03 – enable chrono
It allows to enable and disable all the thermostat functions
programmed; with the set ON you activate this function and it appears the led [ D ] related to it.
When the daily, weekly, or week-end program is set you can see
on the upper right side of the display it appears the led [C].
By accessing the submenu: DAY PROGRAM, the daily
chronothermostat functions can be enabled/disabled and set.
It is possible to set two operation phases delimited by the times
set according to the following table where the OFF setting tells
the clock to ignore the command.
Selection
Meaning
Activation time
Deactivation time
Activation time
Deactivation time
By accessing the submenu: WEEK PROGRAM it is possible to
enable/disable and set the weekly chronothermostat functions.
The weekly programmer has 4 independent programmes whose
final effect consists of a combination of the 4 programmings.
The weekly programmer can be activated/deactivated; also, by
setting OFF in the times field, the clock ignores the
corresponding command.
Carry out programming making sure not to overlap the
hours of activation and/or deactivation on the same day
in different programmes.