Blow-Off Solenoid Valve Set And Suction Solenoid Valve Set For Fxp Only / Kit D'électrovanne Soufflage Et D'électrovanne Aspiration Uniquement Pour Fxp - schmalz FXP Série Notice D'utilisation

Système de préhension de surface par le vide
Table des Matières

Publicité

Bedienungsanleitung
Operating Instructions
30.30.01.01008
8.3 Blow-off solenoid valve set and suction solenoid valve set for FXP only /
Kit d'électrovanne Soufflage et d'électrovanne Aspiration uniquement pour FXP
Item /
Designation
Pos
1
Flange plate (for other dimensions, see above)
2
For the blow off set: blow off solenoid valve =
NC 24 V DC; 8/6 compressed air hose
2
For the suction set:
NO 24 V DC;12/9 compressed air hose
(3)
Vacuum switch VS-V-D-PNP flange plate (optional)
4
4 mounting holes for FXP module
The flange plate is screwed directly onto the FXP module.
The blow-off command or the suction command can be
activated using the solenoid valve. An optional vacuum
switch (item 3) for recording the system vacuum on the FXP
module is available.
FXP(-S)-SVK / FXP(-S)-SW
FXP(-S)-SVK / FXP(-S)-SW
Status 01.2020 / Index 6
suction solenoid valve =
Page - 35 -
J. Schmalz GmbH
Johannes-Schmalz-Str. 1
D - 72293 Glatten
Tel +49 (0) 7443 / 2403 - 0
Fax +49 (0) 7443 / 2403 - 259
www.schmalz.com
schmalz@schmalz.de
Désignation
Bride robot (autres dimensions, voir ci-dessus)
Pour le kit de soufflage : électrovanne Soufflage =
NC 24 V CC ; tuyau d'air comprimé 8/6
Pour le kit d'aspiration :
NO 24 V CC ; tuyau d'air comprimé 12/9
Vacuostat VS-V-D-PNP bride robot (en option)
4 alésages de fixation module FXP
La bride robot est vissée directement sur le module FXP. Le
soufflage actif ou l'aspiration peuvent être commandés au
moyen de l'électrovanne. Il existe en option un vacuostat
(pos. 3) pour relever le vide du système sur le module FXP.
électrovanne Aspiration =