Name and address of relevant, named
location:
TÜV Rheinland LGA Products GmbH
Tillystraße 2
D-90431 Nürnberg
Compilation and storage of technical
documentation:
Sven Zimmermann
STIHL Tirol GmbH
The year of manufacture and machine
number appear on the rating plate of the
machine.
Measured sound power level:
86,0 dB(A)
Guaranteed sound power level:
89 dB(A)
Langkampfen,
2019-01-02 (YYYY-MM-DD)
STIHL Tirol GmbH
p.p.
Head of Design
18. Technical specifications
Type
RLE 540.0
Serial number
6290
0478 670 9906 A - EN
Type
RLE 540.0
Motor, design
Electric motor
Voltage
230 V~
Power input
1600 W
Frequency
50 Hz
Fuse
10 A
Protection class
II
Type of protection
IPX 4
Scarifying device
14 fixed vertical
blades
Scarifying blade
drive
Permanent
Motor output speed
2840 rpm
Working width
38 cm
Working depth
6 levels, adjust-
ment range
25 mm
Wheel diameter
(front)
180 mm
Wheel diameter
(rear)
180 mm
Length
126 cm
Width
54 cm
Height
111 cm
Weight
28 kg
Sound emissions:
In accordance with Directive 2000/14/EC:
Guaranteed sound
power level L
89 dB(A)
WAd
In accordance with Directive 2006/42/EC:
Sound pressure level
at workplace L
72 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1,95 m/sec
hw
Uncertainty K
0,98 m/sec
hw
Type
Measurement in accordance with
EN 20643
18.1 REACH
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.
19. Troubleshooting
If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor not starting
Possible cause:
– No mains voltage
– Scarifying unit not in transport position
– ON button not pressed
– Blade shaft blocked
– Electric cable/plug and plug connector
or switch defective
– Thermal motor overload protection
activated
Remedy:
– Check fuse (
– Place scarifying unit in transport
position (
7.3)
– Press ON button (
– Place scarifying unit in transport
position and clean housing and
discharge chute (disconnect mains
2
plug!) (
7.3), (
2
RLE 540.0
10.1)
10.3)
11.2)
41