1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? t
2. Operation with 2 compressors
3. Operation with 1 comressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7 °C and heating water flow temperature 35 °C.
5. Standard nominal flow only possible with an electronically controlled circulating pump with actuation via heat pump manager.
6. The heat output and COP is reduced by approx. 5 % in lower operation
7. When the optional weather protection hood (accessory) is used, the sound pressure level in outlet direction is reduced by 3 dB(A).
8. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
9. See CE declaration of conformity
10.The heat circulating pump and the heat pump manager must always be ready for operation.
11.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
1
Type and order code
2
Design
Heat source
2.1
Model
2.2
Controller
2.3
Installation location
2.4
Thermal energy metering
2.5
Performance levels
3
Operating limits
3.1
Heating water flow / return
3.2
Air (heating)
3.2
Cooling water flow
3.3
Air (cooling)
4
4
Flow
/ sound
4.1
Heating water flow heat pump circuit / free compression
Nominal flow in accordance with EN 14511
4.2
Minimum heating water flow rate
Heat pump circuit
4.3
Cooling water flow rate / internal pressure differential
Nominal flow in accordance with EN 14511
Minimum cooling water flow rate
4.4
Sound power level according to EN 12102
Normal operation / reduced operation
4.5
Sound pressure level at a distance of 10 m (air outlet side)
Normal operation / reduced operation
4.6
Air flow
Normal operation / reduced operation
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
mm
5.2
Device connections for heating
5.3
Weight of the transportable unit(s) incl. packaging
5.4
Refrigerant / total filling weight
5.5
Lubricant / total filling quantity
5.6
Volume of heating water in device
www.dimplex.de
at A-7 / W35
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W45
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
Haed pump / Hydro tower
1
°C
°C
°C
°C
at A7 / W35...30
m³/h / Pa
at A7 / W45...40
m³/h / Pa
at A7 / W55...47
m³/h / Pa
m³/h / Pa
A35 / W18...23
m³/h / Pa
m³/h / Pa
6 7
dB(A)
8
6 7
dB(A)
6
m³/h
H x W x L
inches
kg
type/kg
type/litres
Litres
452168.66.05 · FD 9512
HPL 9S-TU(R)W - HPL 18S-TU(R)W
5.5 / 3,3
---
7,2 / 3,2
9,5 /
7,2 / 4,3
---
11
4,1(4,3)
8,4 / 4,9
---
11,3 / 4,8
8,2 / 3,8
---
10,8 / 3,9
8,0 / 3,0
---
10,0 / 3,1
8,9 / 5,3
---
12,0 / 5,1
HPL 9S-TURW
HPL 12S-TURW
Air
Reversible with hydro
Reversible with hydro
tower
tower
Integrated (hydro tower)
Integrated (hydro tower)
Outdoors / Indoors
Outdoors / indoors
Integrated
Integrated
1
up to 60 ± 2 / from 18
up to 60 ± 2 / from 18
-22 to +35
-22 to +35
+7 to +20
+7 to +20
+15 to +45
+15 to +45
1,5 / 41000
1,9 / 18000
1,4 / 46000
1,8 / 24000
5
5
0,9
/ 67000
1,2
1,2
1,2 / 56000
1,4 / 46000
1,2 / 56000
1,4 / 46000
53 / 53
54 / 53
25 / 25
26 / 25
2700 / 2100
4700 / 3600
1650 x 910 x 750
1650 x 910 x 750
G 1 1/4" external thread
G 1 1/4" external thread
225
R410A / 3.9
R410A / 4.78
Polyolester (POE)/1.2
Polyolester (POE)/1.2
2.6
---
5,6 / 3,3
10,5 / 3,2
12,3 / 3,9
---
7,3 / 4,3
(4,0)
---
8,4 / 5,0
---
8,1 / 3,9
---
7,7 / 3,2
---
8,8 / 5,4
HPL 18S-TURW
Air
Air
Reversible with hydro
tower
Integrated (hydro tower)
Outdoors / indoors
Integrated
1
2
up to 60 ± 2 / from 18
2
3
-22 to +5
/ +35
3
2
+7
/ +9
to +20
+15 to +45
1,5 / 40900
1,4 / 45900
5
/ 55000
1,4
/ 66900
1,4
1,4
2,2 / 8100
1,6 / 36500
54 / 53
26 / 25
5500 / 3200
1650 x 910 x 750
G 1 1/4" external thread
265
295
R410A / 5,9
Polyolester (POE)/1.2
3.8
3.8
EN-11