Delete programming/factory settings
If anything went wrong during the programming or a
transmitter needs to be replaced, the receiver must first
be reset. To do this, hold down the test button (5) on the
receiver for approx. six seconds. After approx. two seconds,
the red LED (3) lights up; it then flashes briefly four seconds
later. The test button can then be released and the receiver
is returned to the original state, i.e. all transmitters must be
reprogrammed.
Test function
Using the test button on the receiver, you can test the func-
tion of the relay in the receiver. If the test button is pressed
briefly, the relay turns on for approx. one second (click-click).
This function is only available when the window is closed and
the stove in operation.
CE Notes
Strong electric, magnetic or high-frequency fields (discharge,
mobile phones, wireless systems, mobile phones, micro-
waves) may cause the device(s) to malfunction.
CE Compliance
We confirm the conformity of the devices according to the
European Directive 2004/108/EC on electromagnetic
compatibility and the Low Voltage Directive 2006/95/EC.
The radio approval is certified according to the EC R & TTE
Directive 1999/5/EC.
AS-6030_I-Manual_150x180_Fin1.indd 19
Technical data
Mains voltage (receiver)
Breaking capacity
Radio range
Radio frequency
Protection class
Battery (window contact) 1 x type CR 123A
Batteries (transmitter
module thermal sensor)
Technical changes may be made at short notice without
advance warning as part of our product updates and device
optimisation.
SAFETY NOTES
The warranty will be null and void in case of damages arising
from violations of these operating instructions. We are not
liable for consequential damages!
We accept no liability for material damages or injuries arising
from inappropriate use or violation of the safety instructions.
In such cases all warranty claims are null and void!
Do not use this product in hospitals or other medical
facilities. Although this device transmits only relatively weak
radio signals, the signals may in such locations result in
malfunctioning of systems critical to life. The same may
apply to other areas.
For reasons of safety and licensing (CE), unauthorised
conversion and /or modification of the product is prohibited.
19
ENGLISH | AS-6030
230 V ~ , 50/60 Hz,
2W
approx.
1000 W, 4.3 A, at cos phi = 1
up to 20 m
868 MHz
IP 20, for dry rooms only
3 x size AA /Mignon/LR6
alkaline