• DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-
pin XLR input of the VDPL192UV. Multiple VDPL192UVs can be linked through serial linking. The linking cable
should be a two-core screened cable with XLR input and output connectors.
• DMX512 Chain with Termination
• DMX Start Address Selection
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to "listen" to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDPL192UV.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDPL192UVs will "listen" to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will "listen" to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 3-channel VDPL192UV, you will have to set the start address of the first VDPL192UV to 1, the
second VDPL192UV to 4 (1 + 3), the third to 7 (4 + 3) and so on.
8. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
9. Technical Specifications
Power Supply
Power Consumption
Fuse
Dimensions
Total Weight
Max. Ambient Temperature
Max. Housing Temperature
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of
damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.hqpower.com.
The information in this manual is subject to change without prior notice.
VDPL192UV
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
max. 230VAC / 50Hz
25W
2A, 250VAC (5 x 20mm) (order code FF2N)
388 x 247 x 88mm
3kg
45°C
50°C
6
HQPOWER