Option: mains fail options (MF, MFL, MFE, MFU, MFV)
Connector: Six way Molex, 50-37-5063. Crimp terminals: 08-70-1040.
MF/MFL
Pin 1
Inhibit Low
Pin 2
+5V Aux
Pin 3
Power Fail
Pin 4
0V Aux
Pin 5
Inhibit High
Pin 6
NC
Option: PP- Parallel
Connector: Six way Molex, 90142-0006. Crimp terminals: 90119-2109.
Option: PA- Parallel
Connector:
Six way Molex, 90142-0006.
Crimp terminals: 90119-2109.
1
+ve sense
2
Module Good
3
Star Point
4
-ve sense
5
-ve power
6
Star Point
Module good
adjustment pot
Module good link (J3)
MFE
MFU
Enable Low
Inhibit Low
+5V Aux
+5V Aux
Power Fail
Power Fail Emitter
0V Aux
0V Aux
Enable High
Inhibit High
NC
Power Fail Collector
Page 19 of 20
MFV
Inhibit Low
+5V Aux
AC Fail
0V Aux
Inhibit High
SYS Reset
Option IN- inhibit
Connector:
Six way Molex, 90142-0006.
Crimp terminals: 90119-2109.
1
Not connected
2
Module Good
3
Inhibit input
4
Not connected
5
-ve O/P
6
-ve O/P
Module good
adjustment pot
Module good link (J3)
17130 issue 36, September 2018