Alpha 600 Handbook
The RPA option can only be used on modules with output voltages rated up to 32V.
The RP, RPB, RPC and RPD options can only be used on modules with output voltages rated up to 16V.
Not for use with a module voltage range of 18-29V or twin output modules.
ELECTRICAL & THERMAL RATINGS:
Input parameters
NOMINAL INPUT VOLTAGE RANGE
MAX. INPUT VOLTAGE RANGE
INPUT FREQUENCY
MAXIMUM INPUT CURRENT
INRUSH CURRENT
*DC ratings are applicable to specific, non-standard, versions only.
Adjustment and Derating.
The Alpha 600 series is designed to provide a maximum output power of 600W at nominal output voltages. The
following procedure must be used to ensure the PSU is operated within its ratings:
a) Calculate user power for each module (volts x amps).
b) Add all the individual module powers together. The total power must not exceed the power rating of the
converter, 600W.
c) Calculate secondary transformer turns x amps or each module see outputs table for transformer
secondary turns.
d) Add all the module turns x amps together and this must not exceed 120AT.
e) If necessary reduce the loading until the conditions are met. i.e. power and ampere-turns maxima.
Standard modules:
Module
Note
Output range Current Occupied
A
4.5-5.5V
AA
4.5-6.5V
B
4.5-5.5V
BB
4.5-6.5V
C
1, 8
D
8
18-29V
E
2
4.5-5.5V
EB
4.5-5.5V
4.5-5.5V
EQ
2.7-3.9V
F
8
G
8
17.5-29V
18-32V
H
3
18-32V
J
5,8,9
30-48V
K
8
18-29V
L
8,10
1.8-3.2V
M
8
N
6,8
18-32V
18-29V
P
4
Q
8
2.7-3.9V
R
8
2.7-3.9V
S
7,8
2.5-5.7V
T
8
1.8-3.2V
U
8
10-21V
60A
60A
25A
25A
5-16V
16A
8A
5-16V
8A
5-16V
8A
9A
9A
9A
9A
9-16V
33A
25A
5A
5A
10A
15A
25A
5-16V
8A
5A (8)
5A
5-16V
8A
25A
60A
85A
60A
16A
Turns
Slots
2
1
2
1
1
1
1
1
1
2
1
4
2
1
2
1
1
1
1
1
1
2
2
2
4
4
1
4
2
4
2
4
1
1
1
2
1
4
4
1
2
1
1
2
1
2
1
2
1
1
3
Page 15 of 20
100-240VAC or 177- 326VDC*
90-264VAC or 160-358VDC*
47-63Hz
10A AC or 6A DC*
<50 AMPS
Max
Setting for
Current
Hazardous
Limit
Energy
79.2A
>3V
79.2A
>3V
33A
-
33A
-
21.2A
>11.3V
10.6A
>.22.6V
10.6A
-
10.6A
-
11.9A
-
11.9A
-
11.9A
-
11.9A
-
43.6A
>5.5V
33A
>7.2V
6.6A
-
6.6A
-
13A
>18.4V
19.8A
>12V
33A
-
10.6A
-
6.6A
-
6.6A
-
10.6A
-
33A
-
79.2A
>3V
110.5A
>2.2V
79.2A
>3V
21.2A
>11.3V
17130 issue 36, September 2018