Alpha 600 Handbook
Warning – No modification of this product is allowed.
Environmental Specifications:
Description
Use
Temperature
Humidity
Altitude
Pressure
Orientation
Material Group
Pollution Degree
Overvoltage Category
Class
Weight
IP Rating
Level of Insulation:
Dielectric Strength testing is carried out as follows:
Primary mains circuit to earth - 2.25 - 2.35kVDC
Primary mains circuits to transformer core - 4.25 - 4.35kVDC*
Primary mains circuits to secondary -4.25 - 4.35kVDC*
Outputs to each other and to earth are isolated to 500VDC
*This test is not possible with Y capacitors fitted to the unit as damage to these capacitors may occur.
Safety Approvals:
UL60950-1 and CSA22.2 No 60950-1-UL recognised.C-UL for Canada.
IEC/EN60950-1 - CE mark. CE marking when applied to any Alpha 600 product indicates compliance with the Low
Voltage Directive in that it complies with EN60950-1 and with the ROHS Directive.
Fusing: Internal fuse (FS101) 6.3 x 32mm, F12AH/250V
Symbols:
AC
DC
PRODUCTS COVERED
Note: All output voltages/variants may not be available as standard units, refer to datasheet for standard
product range. These (and other variants) may be available as non-standard or custom units, please contact
our sales team for details.
Unit Configuration Code:
Alpha 600, Alpha 600W and CA600 are identical.
(May be prefixed by NS - # / or - where # may be up to any four letters and may be followed by - $; where $
may be any number between 000 and 999, indicating non-safety related model differences.)
Alpha 600 or CA600 may be followed by: TL, RL, LL, ML, A or no letter,
where TL = Tiny leakage input filter
RL = Reduced leakage input filter
LL = Low leakage input filter
Operation
Indoor
0 to 50°C (derating 2.5%°C above 50°C to 65°C -
Not covered by approvals).
5 to 95% RH non-condensing.
-200m to 3000m
70kPa to 106kPa
Horizontal, on either side or vertical with
airflow upwards.
EARTH
Page 13 of 20
IIIb
2
II
I
2.4 Kg (Dependent on configuration)
IPX0
N – Neutral
Storage
-
-40°C to +85°C
5% to 95% RH non-
condensing
-200m to 5000m.
54kpa to 106kpa
All
L – Live
17130 issue 36, September 2018