Designation
0x1604
0x00
Receive PDO
mapping
Number of
mapped
objects in
PDO
0x01
PDO map-
ping
0x02
PDO map-
ping
0x03
PDO map-
ping
0x04
PDO map-
ping
Data type
Default
rw
USINT
0x04
rw
UDINT
0x6414 0D10
rw
UDINT
0x6414 0E10
rw
UDINT
0x6414 0F10
rw
UDINT
0x6414 1010
Details (CR2051)
Mapping read PDO 5:
PWM outputs OUT12...OUT15
number of integrated application
objects = 4
PWM/ current output OUT12
Index 0x6414, SubIndex 0x0D
contains the preset value of the
PWM output OUT12, the value is
interpreted as duty cycle in ‰ or as
target current value (depending on
the configuration index 0x2000)
PWM/ current output OUT13
Index 0x6414, SubIndex 0x0E
contains the preset value of the
PWM output OUT13, the value is
interpreted as duty cycle in ‰ or as
target current value (depending on
the configuration index 0x2000)
PWM/ current output OUT14
Index 0x6414, SubIndex 0x0F
contains the preset value of the
PWM output OUT14, the value is
interpreted as duty cycle in ‰ or as
target current value (depending on
the configuration index 0x2000)
PWM/ current output OUT15
Index 0x6414, SubIndex 0x10
contains the preset value of the
PWM output OUT15, the value is
interpreted as duty cycle in ‰ or as
target current value (depending on
the configuration index 0x2000)
ioControl
UK
77