10. ATEX certification:
• ATEX certificate number
• Classification for zone type, protection method, temperature class for which this product may be used in
compliance with the ATEX directive
ATEX MARKING
Ambient temperature
-40°C to +65°C
-40°C to +70°C
Tab. 4
11. IECEx certification:
• IECEx certificate number
• Classification for zone type, protection method and temperature class for which this product may be used
in compliance with the IECEx standard
IECEX MARKING
Ambient temperature
-40°C to +65°C
-40°C to +70°C
Tab. 5
The housing may feature additional labels for the markings of other certifications.

5 Product coding

MAXIMUS MMX - PRODUCT CODING
Voltage
MMX
2 24Vac/24Vdc, PoE+
Tab. 6
MNVCMMX_1821_EN
Gas marking
II 2 G Ex db IIB T6 Gb
II 2 G Ex db IIB T5 Gb
Gas marking
Ex db IIB T6 Gb
Ex db IIB T5 Gb
Camera
0 Without camera
* Pre-installed camera * Connection devices
Dust marking
II 2 D Ex tb IIIC T85°C Db
II 2 D Ex tb IIIC T100°C Db
Dust marking
Ex tb IIIC T85°C Db
Ex tb IIIC T100°C Db
Connection
Video output
0 Without cable,
0 With a video
without cable gland
Z With a video enco-
* For internal use
encoder integrated
in the camera
der preinstalled by
the manufacturer
11