8 Installation

Do not open the device when powered and
in explosive atmosphere.
Make all connections, installation and
maintenance work in a non-explosive
atmosphere.
Make sure that all the equipment are
certified for the application and for the
environment in which they will be installed.
CAUTION! The electrical system to which the
unit is connected must be equipped with a
10A max automatic bipolar circuit breaker.
The minimum distance between the circuit
breaker contacts must be 3mm (0.1in). The
switch must be equipped with protection
against overcurrent (circuit breaker).
Electrical connections must be performed
with the power supply disconnected and
the circuit-breaker open.
A power disconnect device must be
included in the electrical installation, and
it must be very quickly recognizable and
operated if needed.
Be careful not to use cables that seem worn
or old.
CAUTION! Device installation and
maintaining must be performed by
specialist technical staff only.
20
Comply with all the national standards
during the device installation.
All disconnected wires must be electrically
isolated.
The cameras to be installed shall not
contain cells or batteries.
VIDEOTEC strongly recommend to test the
device configuration and performance
before putting it in the final installation
site.

8.1 Cable entry

To prevent the spread of flames or explosions from
the unit to the conduit system or cable gland to the
external environment, use connection in conformity
with IEC/EN60079-14.
Non-sheathed single cores shall not be used, unless
they are installed inside conduit systems.
All cable glands shall be ATEX/IECEx certified, as
appropriate, in type of explosion protection "db" and/
or "tb", rated IP66/IP68, suitable for the conditions of
use and correctly installed.
It is compulsory to install a resin-treated device
between the housing and the safe area (barrier cable
gland or stopping box).
When conduit is used, a suitable ATEX/IECEx certified
stopping box shall be used, as appropriate, in type
of explosion protection "db" and/or "tb", rated IP66/
IP68, suitable for the conditions of use and correctly
installed. The stopping box must be fitted within
50mm (1.97in) from the enclosure wall.
MNVCMMX_1821_EN