Display
= Display
Reverse
rotation
Display Back-
= Display
light
lighting
DMX Fail
= Operating
status when
DMX signal
fault occurs
Dimmer
= Dimmer
Curve
curve
Power Mode
= Operating
mode
Dimmer
= Dimmer
response
response
Autolock
= Automatic
locking of
controls
PWM Fre-
= LED PWM
quency
frequency:
On
Display is rotated by 180° (e.g. for overhead
installation)
Off
No rotation of the display
On
permanently on
Off
Deactivation after approximately 1 minute of
inactivity
Hold
last command is retained
Blackout
Activates blackout
Full On
Spotlight switches to full on
Stand-alone
Spotlight switches to stand-alone mode
Linear
Light intensity increases linearly with DMX
value
Exponential
Light intensity can be finely adjusted at lower
DMX values and broadly adjusted at higher
DMX values
Logarithmic
Light intensity can be broadly adjusted at low-
er DMX values and finely adjusted at higher
DMX values
S-curve
Light intensity can be finely adjusted at lower
and higher DMX values and broadly adjusted
at medium DMX values
Normal
Constant brightness
Boost
Brief maximum brightness (approx. 3 seconds)
LED
Lamp responds abruptly to changes in DMX
value
Halogen
Spotlight behaves like a halogen spotlight with
soft brightness changes
On
Automatic locking of the controls after approx-
imately 1 minute of inactivity. After attempted
input the display shows: "Locked!"
Unlock: press and hold UP and DOWN simulta-
neously for approx. 5 seconds
Off
Automatic locking of the controls is disabled
800 Hz/1200
Configuration of LED PWM frequency
Hz/2000 Hz/
3600 Hz/12
kHz/25 kHz