Location Requirements - Jenn-Air JJW2427DB Instructions D'installation

Masquer les pouces Voir aussi pour JJW2427DB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parts Supplied
Deflector bracket
Plastic spacers - (4) single ovens, (6) double ovens
#8-18 x 1/4" (6.3 mm) screws - (2) for 27" (68.6 cm) models;
(4) for 30" (76.2 cm) models

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
NOTE: Refer to the following "Location Requirements" and the
"Location Requirements" section of the Installation Instructions
provided with your built-in oven.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
Oven support surface must be solid, level, and flush with
bottom of the cabinet cutout.
Floor must be able to support a single oven weight of
180 lbs (82 kg).
Floor must be able to support a double oven weight of
357 lbs (162 kg)
IMPORTANT: To avoid damage to your cabinets, check with
your builder or cabinet supplier to make sure that the materials
used will not discolor, delaminate, or sustain other damage. This
oven has been designed in accordance with the requirements
of UL and CSA International and complies with the maximum
allowable wood cabinet temperatures of 194°F (90°C).
Deflector Bracket Dimensions
27" (68.6 cm) Models
A. 26
" (68.4 cm) overall width
15
16
Cabinet Dimensions - Single Ovens, Flush
Installations
A 25" (63.5 cm) minimum cutout depth is required.
These dimensions will result in a 1⁄4" (6.3 mm) reveal on the top,
a 1⁄4" (6.3 mm) reveal on the sides, and a 1⁄8" (3.1 mm) reveal on
the bottom of the wall oven.
The front face of the cleats and platform will be visible and
should be treated as a finished surface.
06-May-2019 13:38:41 EDT | RELEASED
A
30" (76.2 cm) Models
A. 29
" (76.0 cm) overall width
15
16
In some European factories the letter "W" of the part code mentioned herein will be automatically
Single Ovens Installed in Cabinet - Flush Installation
A
B
C
D
E
F
G
H
Front View
27" (68.6 cm) Models
A. 3/4" (19 mm) top cleat*
B. 27
/
" (69.2 cm) minimum width
1
4
of flush inset cutout
C. 25
/
" (65.7 cm) minimum width
7
8
of opening
D. 30
/
" (77.3 cm) minimum
7
16
height of flush inset cutout
E. 29
/
" (75.4 cm) recommended
11
16
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
/
" - 32" (11.7 cm- 81.3 cm)
5
8
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
*Cleats and spacers must be recessed 1
front of the cabinet.
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")
F
G
J
H
I
Side View
30" (76.2 cm) Models
A. 3/4" (19 mm) top cleat*
B. 30
/
" (76.8 cm) minimum width
1
4
of flush inset cutout
C. 28
/
" (73.3 cm) minimum width
7
8
of opening
D. 30
/
" (77.3 cm) minimum
7
16
height of flush inset cutout
E. 29
/
" (75.4 cm) recommended
11
16
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
5
/
" - 32" (11.7 cm - 81.3 cm)
8
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
" (3.5 cm) from the
3
/
8
3

Publicité

Table des Matières
loading