Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided with
any tools listed here.
Tools Needed
Phillips screwdriver
■
Measuring tape
■
Hand or electric drill (for wall cabinet installations)
■
1" drill bit (for wall cabinet installations)
■
Level
■
Flat-blade screwdriver
■
Parts Needed
UL listed or CSA approved conduit connector
■
UL listed wire connectors
■
Warming Drawer Deflector Kit (for ovens installed
■
above a warming drawer)
Black 30" (76.2 cm) kit
Stainless steel 30" (76.2 cm) kit
To order, see the "Assistance or Service" section
of the Use and Care Guide.
Flush Installation Kit (for Single and Double installed at flush
■
installation)
Black 30" (76.2 cm) kit
Stainless steel 30" (76.2 cm) kit
To order, see the "Assistance or Service" section
of the Use and Care Guide.
Parts Supplied
#8-14 x 1" (2.54 cm) screws - single ovens (2), double
■
ovens (4)
#8-18 x 3/8" (9.5 mm) screws - bottom vent (2)
■
#8-18 x 1/4" (6.6 mm) screws - bottom vent trim (4)
■
2
BUILT-IN OVEN SAFETY
INSTALLATION REQUIREMENTS
#8-18 x 3/8" (9.5 mm) screws - double oven feet (4)
■
Bottom vent
■
Bottom vent trim
■
Rear feet - double oven (2)
■
Front feet - double oven (2)
■
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
■
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete enclosure
■
around the recessed portion of the oven.
Grounded electrical supply is required. See
■
"Electrical Requirements" section.
Electrical supply junction box should be located 3" (7.6 cm)
■
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should have been drilled in the right rear or left rear
corner of the support surface to pass the appliance cable
through to the junction box.
NOTE: For undercounter installation, it is recommended
that the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, it is recommended that the junction box be
recessed and located in the upper center of the cabinet.
Oven support surface must be solid, level, and flush
■
with bottom of cabinet cutout.
Floor must be able to support a single oven weight
■
of 180 lb (82 kg).