27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC
SINGLE AND DOUBLE BUILT-IN OVEN
FOUR ÉLECTRIQUE ENCASTRÉ 27" (68,6 CM) ET 30"
BUILT-IN OVEN SAFETY ...............................................................2
INSTALLATION REQUIREMENTS ................................................2
Tools and Parts ............................................................................2
Location Requirements................................................................3
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ..................................................7
Prepare Built-In Oven...................................................................7
Remove Oven Door(s) ..................................................................7
Replace Oven Door(s) ..................................................................7
Make Electrical Connection .......................................................13
Install Oven.................................................................................14
Above Warming Drawers) ..........................................................15
Complete Installation .................................................................16
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10768183A
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION
(76,2 CM) - SIMPLE ET DOUBLE
Table of Contents/Table des matières
SÉCURITÉ DU FOUR ENCASTRÉ ..............................................17
EXIGENCES D'INSTALLATION ...................................................17
Outillage et pièces......................................................................17
Exigences d'emplacement.........................................................18
Spécifications électriques ..........................................................21
INSTRUCTIONS D'INSTALLATION.............................................22
Préparation du four encastré .....................................................22
Dépose de la/des porte(s) du four .............................................22
Réinstallation de la/des porte(s) du four ....................................23
d'encastrement de hauteur différente........................................24
Raccordement électrique...........................................................28
Installation du four......................................................................29
réchaud)......................................................................................31
Achever l'installation ..................................................................32

Publicité

Table des Matières
loading

Sommaire des Matières pour Jenn-Air JJW2430DS

  • Page 1: Table Des Matières

    INSTALLATION INSTRUCTIONS 27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN INSTRUCTIONS D’INSTALLATION FOUR ÉLECTRIQUE ENCASTRÉ 27" (68,6 CM) ET 30" (76,2 CM) - SIMPLE ET DOUBLE Table of Contents/Table des matières BUILT-IN OVEN SAFETY ...............2 SÉCURITÉ...
  • Page 2: Built-In Oven Safety

    BUILT-IN OVEN SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 3: Location Requirements

    Location Requirements IMPORTANT: Observe all governing codes and ordinances. Undercounter Installation (With Cooktop Installed Above): Cabinet opening dimensions that are shown must be used. Ovens approved for this type of installation have an approval Given dimensions provide minimum clearance with oven. label located on the top of the oven.
  • Page 4: Cabinet Dimensions - Single Ovens

    Single Ovens Installed in Cabinet Cabinet Dimensions - Single Ovens Single Oven Undercounter (Without Cooktop Installed Above) 27" (68.6 cm) models 30" (76.2 cm) models A. 27" (68.6 cm) min. cabinet A. 30" (76.2 cm) min. cabinet width width ¹⁄₂ ¹⁄₂...
  • Page 5: Product Dimensions - Double Ovens

    Product Dimensions - Double Ovens Cabinet Dimensions - Double Ovens Double Ovens Installed in Cabinet 27" (68.6 cm) models 30" (76.2 cm) models ³⁄₈ ³⁄₈ 27" (68.6 cm) models 30" (76.2 cm) models A. 53 " (133.0 cm) max. overall A.
  • Page 6: Electrical Requirements

    Electrical Requirements If codes permit and a separate ground wire is used, it is Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW recommended that a qualified electrical installer determine at 208 volts) require a separate 40-amp circuit. Models that the ground path and the wire gauge are in accordance rated at 4.8 kW and below at 240 volts (3.6 kW and below with local codes.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS 4. Partially close the door to engage the door latch locks. The Prepare Built-In Oven door will stop at this point. 1. Decide on the final location for the oven. Avoid drilling or cutting into house wiring during installation. WARNING Excessive Weight Hazard Use two or more people to move and install oven.
  • Page 8: Positioning Oven Feet For Multiple Cabinet Cutout Heights

    3. At a 45° angle, align door hinges with slots in the lower front of the oven cavity. Slowly insert door, making sure you Positioning Oven Feet for Multiple Cabinet maintain the 45° angle. You will know the door is engaged in Cutout Heights the slot when you feel a slight drop.
  • Page 9 Cutout Height is Between 26¹⁵⁄₁₆" and 27¹¹⁄₁₆" (68.4 cm and Cutout Height is Between 28¹¹⁄₁₆" and 29⁷⁄₁₆" (72.8 cm and 70.3 cm) 74.8 cm) 1. Using 2 or more people, place the oven on its back on a 1. Using 2 or more people, place the oven on its back on a covered surface.
  • Page 10 6. Using 2 or more people, place the oven in its upright position. Double Ovens The positioning of the oven feet allow a double oven to be installed in a cutout height between 48⁷⁄₈" and 52³⁄₁₆" (124.1 cm and 132.6 cm). Refer to the following instructions to position the feet for the size of your cabinet cutout.
  • Page 11 4. Install a front foot on the left front spacer using a #8-18 x ³⁄₈" Cutout Height is Between 50¹⁄₂" and 51¹⁄₈" (128.2 cm and 129.9 cm) screw. NOTE: Position the foot so the long side of the foot is facing 1.
  • Page 12 Cutout Height is Between 51³⁄₁₆" and 52³⁄₁₆" (130.0 cm and 5. In the same manner, install a font foot on the right front of the 132.6 cm) oven. 1. Using 2 or more people, place the oven on its back on a 6.
  • Page 13: Make Electrical Connection

    Make Electrical Connection For Double Ovens For Single Ovens WARNING WARNING Electrical Shock Hazard Electrical Shock Hazard Disconnect power before servicing. Disconnect power before servicing. Use 8 gauge solid copper wire. Use 12 gauge solid copper wire. Electrically ground oven. Electrically ground oven.
  • Page 14: Install Oven

    3-Wire Cable from Home Power Supply - U.S. Only Install Oven 1. Using 2 or more people, lift the oven partially into the cabinet IMPORTANT: Use the 3-wire cable from home power supply cutout. Use the oven opening as an area to grip. where local codes permit a 3-wire connection.
  • Page 15: Install Warming Drawer Deflector Kit (Only For Ovens Installed Above Warming Drawers)

    5. The bottom vent and bottom vent trim (required when the Align vent tab (B) with oven frame (A) as shown. oven is installed with the feet in the tall position) are shipped Using one #8-18 x ³⁄₈" screw (E) on each side of the vent in the foam packing at the top of the oven.
  • Page 16: Complete Installation

    Install Deflector Kit Complete Installation 1. Flex the upper vent piece (C) away from the lower vent piece (D) to slide the warming drawer deflector (B) between them. 1. Check that all parts are now installed. If there is an extra part, Some force may be required to flex the upper vent trim (C) go back through the steps to see which step was skipped.
  • Page 17: Sécurité Du Four Encastré

    SÉCURITÉ DU FOUR ENCASTRÉ Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 18: Exigences D'emplacement

    Exigences d'emplacement IMPORTANT : Observer les dispositions de tous les codes et Installation sous un plan de travail (avec table de cuisson règlements en vigueur. installée au-dessus) : Respecter les dimensions indiquées pour les ouvertures à Les fours homologués pour ce type d'installation comportent une découper dans les placards.
  • Page 19 Fours simples installés dans un placard Dimensions du placard - Fours simples Four simple sous le plan de travail (sans table de cuisson au- dessus) Modèles de 27" (68,6 cm) Modèles de 30" (76,2 cm) A. Largeur du placard 27" A.
  • Page 20 Dimensions du produit - Fours doubles Dimensions du placard - Fours doubles Fours doubles installés dans un placard Modèles de 27" (68,6 cm) Modèles de 30" (76,2 cm) ³⁄₈ ³⁄₈ Modèles de 27" (68,6 cm) Modèles de 30" (76,2 cm) A.
  • Page 21: Spécifications Électriques

    Spécifications électriques Si on utilise un conducteur distinct de liaison à la terre lorsque les Un modèle de 7,3 à 9,6 kW/240 volts (5,4 à 7,4 kW/208 volts) codes le permettent, il est recommandé qu'un électricien qualifié doit être alimenté par un circuit indépendant de 40 A. Un vérifie que la liaison à...
  • Page 22: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION 4. Fermer partiellement la porte pour engager les loquets de la Préparation du four encastré gâche de porte. La porte restera bloquée à cette position. 1. Choisir l'emplacement final pour l'installation du four. Éviter de percer ou d'endommager le câblage lors de l'installation. AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et...
  • Page 23: Réinstallation De La/Des Porte(S) Du Four

    Réinstallation de la/des porte(s) du f3our 1. Saisir les bords latéraux de la porte par le milieu avec les 4. Abaisser la porte du four jusqu'à ce qu’elle soit deux mains. Se placer face à la cavité du four. complètement ouverte. Si la porte du four ne s'ouvre pas complètement à...
  • Page 24: Positionnement Des Pieds Du Four Pour Des Ouvertures D'encastrement De Hauteur Différente

    Positionnement des pieds du four pour des ouvertures d'encastrement de hauteur différente 2. Retirer le pied de la cale d'espacement avant droite en ôtant la vis n° 8-18 x ³⁄₈". Four simple REMARQUE : Ne pas retirer la cale d'espacement. En modifiant le positionnement des pieds du four, on peut installer un four simple dans une cavité...
  • Page 25 2. Retirer le pied de la cale d'espacement avant droite en ôtant la vis n° 8-18 x ³⁄₈". Fours doubles REMARQUE : Ne pas retirer la cale d'espacement En modifiant le positionnement des pieds du four, on peut installer un four double dans une cavité d'encastrement d'une hauteur comprise entre 48⁷⁄₈"...
  • Page 26 La hauteur de la cavité d’encastrement est comprise entre 5. De la même manière installer un pied avant sur la partie avant 50¹⁄₂" et 51¹⁄₈" (128,2 cm et 129,9 cm) droite du four. 1. À l'aide d'au moins 2 personnes, placer le four sur sa partie 6.
  • Page 27 La hauteur de la cavité d’encastrement est comprise entre 4. Installer un pied avant sur la partie avant gauche avec une vis n° 8-18 x ³⁄₈". 51³⁄₁₆" et 52³⁄₁₆" (130,0 cm et 132,6 cm) 1. À l'aide d'au moins 2 personnes, placer le four sur sa partie REMARQUE : Positionner le pied de façon à...
  • Page 28: Raccordement Électrique

    Raccordement électrique Fours doubles Fours simples AVERTISSEMENT AVERTISSEMENT Risque de choc électrique Risque de choc électrique Déconnecter la source de courant électrique avant Déconnecter la source de courant électrique avant l'entretien. d'entreprendre le travail. Utiliser du fil en cuivre rigide de calibre 8. Utiliser du fil en cuivre rigide de calibre 12.
  • Page 29: Installation Du Four

    Câble à 4 conducteurs depuis le point de distribution du Câble à 3 conducteurs depuis le point de distribution du domicile domicile - É.-U. seulement IMPORTANT : Utiliser le câble à 4 conducteurs provenant IMPORTANT : Utiliser le câble à 3 conducteurs depuis le point du point de distribution du domicile aux États-Unis lorsque de distribution du domicile lorsque les codes locaux autorisent les codes locaux ne permettent pas la mise à...
  • Page 30 2. Pousser contre la zone du joint du châssis avant pour 5. L'évent inférieur et la garniture de l'évent inférieur introduire le four dans le placard, jusqu'à ce que la surface (nécessaires lorsque le four est installé avec les pieds arrière du châssis avant soit au contact de la paroi avant du en position haute) sont livrés dans l'emballage en mousse placard.
  • Page 31: Installation De L'ensemble De Déflecteur Du Tiroir-Réchaud (Uniquement Pour Les Fours Installés Au-Dessus D'un Tiroir-Réchaud)

    6. Pour les modèles dont les pieds sont installés en position 7. Réinstaller les grilles du four. haute, la garniture de l'évent inférieur doit également être 8. Réinstaller la porte du four. Voir la section “Réinstallation de installée. Pour l’installation, procéder selon les instructions la/des porte(s) du four”.
  • Page 32: Achever L'installation

    3. Aligner le support de l'évent (B) avec le châssis du four (A) comme illustré. Achever l’installation 4. Avec une vis n° 8-18 x ³⁄₈" (E) pour chaque côté du support de 1. Vérifier que toutes les pièces sont maintenant installées. S’il l'évent (B), fixer solidement l'évent au four.