P1 and P3: Buttons to set the power
level
P5: Button for accessing the MENU
P7: Button to activate/deactivate
ECO mode
P9: On/Off button and for exiting the
MENU
4.7.1 Replacing the battery
The remote control is powered by a 3-volt CR2025 type battery located in the bottom of the device. For its insertion
and possible replacement, proceed as follows:
- Operate the lever indicated;
- Pull out the battery tray and replace the battery (3-volt CR2025 model) respecting the polarity;
- Insert the tray;
- Check proper functioning.
- Keep the remote control away from direct heat sources and water.
- The remote control battery must be replaced and disposed of safely in compliance with local
regulations;
4.8 Thermostat - external chronothermostat
The standard unit controls the room temperature by means of a digital probe that adjusts the power according to the
set temperature.
To use an additional thermostat, contact an authorised technician and proceed as follows:
turn off the power at the main switch (if available) and disconnect the power cable;
remove the panels to gain access to the main board;
referring to the wiring diagram, connect the two thermostat wires to the respective terminals TERM on the
board (use a 'normally open' type thermostat);
refit everything and check proper functioning
Then set as follows:
external thermostat: set a temperature of 7°C;
external chronothermostat: set a temperature of 7°C, disable the chrono functionality in the menu 03 and
set the STANDBY function to ON. When the set temperature is reached, the stove will shut down and not
go to modulation.
In this case, however, it is advisable to use the stove time programming function and only the external
chronothermostat set temperature function.
In fact, only with this joint setting is it possible to set STANDBY to ON or OFF, obtaining respectively
modulation or shutdown when the SET temperature is reached and likewise obtaining shutdown and lighting
according to the set time programming.
When the external thermostat requests stove operation, the corresponding symbol will light up on the display.
P2 and P4: Buttons to set the room
temperature
P6: Button to exit the MENU
P8: Button to activate/deactivate
STANDBY mode
P10: Button to activate/deactivate
the CHRONO function
battery tray
lever
41