After a certain time has elapsed, if the fume temperature has not reached the minimum permissible value the stove
goes in alarm status.
- Do not use flammable liquids to light the stove.
- In case of persistent failed lighting, contact the Service Centre.
4.4 Work stage
After the 'STARTUP' stage, the stove goes to the 'WORK' mode which represents the normal operation mode.
The user can adjust the heat output from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
As well as adjusting the heat output, it is also possible to adjust the room temperature directly on the control panel
with the buttons 'P1' and 'P2': the display shows the current SET temperature status.
For the ventilation of hot air, the stove automatically regulates the speed according to the set heat output.
Button 'P1'
Button 'P2'
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of
pellets.
- Make sure the stove is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the stove.
When the fume temperature rises the maximum value set, the
display will show the message 'MODULA F' and the stove starts
the modulation of the flame authomatically. On the contrary when
the temperature goes over 280°C the display will show the alarm
'ALARM HOT FUMI' and the stove will start the switch-off
procedure.
If the STANDBY mode is activated, the stove is shut down with a
delay time after reaching the SET temperature. Restart occurs
when the room temperature is lower than a certain fixed value with
respect to the room temperature.
Clock
Room temperature
Output set to 4
Dialogue box
Room temperature set value
Dialogue box
Clock
Dialogue box
47
Button 'P6'
Button 'P5'
Room temperature
Output
LOTO HR