- it must ensure an adequate dilution of fumes and be positioned outside the backflow area;
- it must be without mechanical means of suction.
The direct discharge of fumes must take place on the roof and not towards closed spaces
( even open air ).
2.5 Brazier and baffle position check
Before lighting the stove make sure the brazier is in the correct position, i.e. fitted in the special slots. Also make
sure the top smoke baffle is properly fitted. A wrongly positioned baffle can result in malfunctioning and excessive
blackening of the glass.
At every stove lighting, check the correct position of the brazier on the brazier holder.
2.6 Electrical connection
Connect one end of the power cable to the rear socket of the stove, and the other to the wall socket.
The voltage supplied by the system must match that specified on the stove dataplate and in the technical data
section of this manual.
During stove idle periods it is advisable to remove the power cable.
- Make sure the electrical system is equipped with an earth and differential switch in accordance with the
current Regulations.
- The power cable must never touch the stove exhaust pipe.
2.7 Wiring diagram
PELLET LEVEL
PRESSURE
TRANSDUCER
INPUTS
NTC
probe
room
probe
suppl.
thermostat
fume
probe
2.8 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using suitable fire-extinguishers.
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
PLC additional
accessories and console
AIR FLOW METER
IGNITER
EXCHANGER 2
AUGER
Fume verifier encoder
SYSTEM
FUME EXTRACTION
EXCHANGER 1
FAN
42
EARTH
EXCHANGER 3
ALF = main safety thermostat
ALC = low pressure gauge
FOCUS HR