4.3 Lighting
4.3.1 Check before lighting
Before lighting the stove:
- make sure you have read and understood that given in the manual;
- the hopper must be filled with pellets;
- the combustion chamber must be clean;
- the brazier must be completely free, cleaned of any combustion residuals and correctly fitted in the brazier
holder;
- check hermetic closing of the fire door and ash pan;
- check the connection of the power cable and switching to ON/1 of the switch located on the back of the stove.
- At first startup, remove all the components (instructions/label) that could burn from the stove firebox
and glass.
- Any lightings done after long stove idle periods require the renewal of any pellets that have been inside
the hopper for a long time, in being a damp fuel no longer suitable for combustion, and complete
cleaning of the combustion chamber.
4.3.2 Startup stage
To light the stove, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
The stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
The stove carries out the startup stages in sequence according to the procedures defined by the parameters that
manage levels and times, reaching the work condition unless anomalies or alarms occur, according to the following
table:
Status
OFF
START – CLEANING
PREHEAT
PELLET PREFILL
WAITING FLAME
PELLET LOAD
FIRE PRESENT
WORK
MODULATES WORK
BRAZIER CLEANING
WORK
FINAL CLEANING
Clock
Room temperature
Dialogue box
Duration
Devices
Fume
Igniter
exhaust
Output
Button 'P4'
Conditions for going to next status
Auger
Exch.
After time Pr33
After timePr34
After time Pr40
After timePr41
Fume temperature > Pr13
After time Pr02
Room temperature < SET temperature
Fume temperature < Pr14
Room temperature < SET temperature
Fume temperature < Pr14
Every Pr03
ON/OFF to switch off
(*) Pr39 starts from when fume T.< Pr13
44