2.2.4 Transmission of a daily Keep Alive frame

In the event mode (threshold or digital), it is possible that the product would never send data frames. So to be sure that it is working properly a
Keep Alive frame is transmitted regularly according to the following diagram:
In periodic mode there is no Keep Alive frame transmission.
The settings associated with this mode of operation are:
• The setting of the period of transmission of the Keep Alive frame (once per hour to once per day) (register 300).
A complete list of the registers can be found in paragraph 3.4.
E.g.:
Register
S300
Value encoding
Decimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Product in standby
Period
reached?
Send frame 0x30
Value encoding
Decimal
Value
Result
0
Event mode
0x02
Channel A configured for a sensor 4-20mA
0x01
Channel B configured for a sensor 0-10V
0x1C
Channel A:
No threshold detection
Event detection on digital input on rising and falling
edges
• Waiting* period of 10ms
0x18
Channel B:
No threshold detection
Event detection on digital input on rising edge only
• Waiting* period of 10ms
No
Yes
Value
Result
72
The Keep Alive frame is sent every: 72x10=720min i.e.
12h (or twice per day)