Anleitung_BG-DP_1340_G_SPK7:_
11. Troubleshooting guide
Faults
The equipment does not start
The equipment does not pump
The equipment does not cut out
Insufficient pumping rate
The equipment switches off after
briefly running
04.08.2011
15:12 Uhr
Cause
- Power supply not connected
- Floating switch does not work
- Intake sieve clogged
- Discharge hose kinked
- Floating switch cannot sink
- Intake sieve clogged
- Performance reduced due to
heavily contaminated and
abrasive water impurities
- Motor circuit-breaker switches
the equipment off due to
excessive water contamination
- Water temperature too high;
motor circuit-breaker switches
the equipment off
Seite 15
Remedy
- Check the power supply
- Raise the position of the floating
switch
- Clean the intake sieve with a
water jet
- Unkink the hose
- Place the equipment correctly on
the shaft bottom
- Clean the intake sieve
- Clean the equipment and replace
wear parts
- Pull out the power plug and
clean the equipment and shaft
- Ensure that the maximum
permissible water temperature
(35 °C) is not exceeded
GB
15