Manual Instructions: Rotomolded Portable Foam Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
User Manuals for Models:
FI-25 Mobyfoam
Specifications:
Hose ...................33 feet reinforced hose, 3/4 inch I.D.
(10 meters reinforced hose, 3/4 inch I.D.)
Foam output.......20 to 45 gallons/minute
(75 to 175 liters/minute)
Requirements:
Compressed air 40 to 80 PSI (3 to 5 bar) with 5 to 10 CFM
(141.64 to 283.30 l/min)
Chemical requirements: follow all instructions from chemical
manufacturer.
WARNING
Avoid Personal Injury
1. Always wear protective clothing, gloves, and
eyewear while operating foam unit.
2. Avoid contact of cleaning agent with skin and eyes.
If contact occurs, see MSDS sheet for further first
aid measures.
3. Follow safety instructions of chemical manufacturer
(MSDS).
4. After each use, relieve all remaining pressure in
the system by unplugging the air line from the unit
and opening the discharge ball valve to prevent
accidental discharge.
5. Never point the discharge wand at anyone.
6. After relieving the pressure from the unit, store the
unit with the ball valve in the closed position.
Air Operated double Diaphragm Pump Models Offered:
P56..............Flojet polypropylene body with Santoprene
diaphragm
P56V............ Flojet polypropylene body with Viton diaphragm
P56K............ Flojet polypropylene body with Kalrez diaphragm
Acceptable Products:
Sanitizers, and Acids.
* D-Limonene may only be used with Kalrez pump
* Chlorine may only be used with Viton or Kalrez pump
DO NOT USE: All hydrocarbons
CAUTION
Avoid Equipment Damage
1. Only use clean and dry air. Air must be filtered and free
of moisture or pump life will be diminished. If needed,
install air dryer before unit.
2. Do not use air lubricator before the unit.
3. Be sure to flush the unit with fresh water for 5 minutes
when switching from an alkaline to an acid or an acid to
an alkaline.
4. Do not exceed a fluid temperature of 100 degrees
Fahrenheit (37oC).
Alkaline cleaners, Caustic cleaners,
06022010