again by any unauthorized person.
G
Warning!
Store the compressor only in a dry location which is
B
not accessible to unauthorized persons.
Always store upright, never tilted!
7.4.1 Storage
The compressor may be placed in a vertical position,
standing on rubber feet for storage purposes only (as
shown in Figure 5).
9. TROUBLESHOOTING GUIDE
Note: Remove power source and drain tank pressure prior to making any repairs or adjustments.
FAULT
Leakage of air from the valve of the
pressure switch with the compressor
off.
Reduction of performance. Frequent
start-up. Low pressure values.
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the
compressor stops.
The compressor does not stop and
the safety valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original parts.
Tampering with the machine may impair its safety and in any case make the warranty null and void.
8. DISPOSAL AND RECYCLING
The unit and its accessories are made of various types of
material, such as metal and plastic.
Defective components must be disposed of as special
waste. Ask your dealer or your local council.
CAUSE
Check valve that, due to wear or
dirt on the seal, does not perform its
function correctly.
Excessive performance request,
check for any leaks from the
couplings and/or pipes. Intake filter
may be clogged.
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal
of the plug with the compressor
running, low power voltage).
Irregular functioning of the
compressor or breakage of the
pressure switch.
16
REMEDY
Unscrew the hexagonal head of the
check valve, clean the valve seat
and the special rubber disk (replace
if worn). Reassemble and tighten
carefully.
Replace the seals of the fitting, clean
or replace the filter.
Clean the air ducts in the conveyor.
Ventilate the work area.
Activate the on/off switch. Ventilate
the work area. Wait a few minutes.
The compressor will restart
independently.
Remove the plug and contact the
Service Center.