Télécharger Imprimer la page

TDK-Lambda RFE1000-24 Mode D'emploi page 13

Masquer les pouces Voir aussi pour RFE1000-24:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
RFE 1000 SERIES INSTRUCTION MANUAL
RFE1000 SERIES SPECIFICATIONS
Rated output voltage
1
Output voltage set point
2
Output voltage range
3
Maximum Output Current (Refer to Fig.1)
4
Maximum output power
5
Input voltage / frequency range
6
Maximum input current (at 100/200Vac)
7
Power Factor (Typ) (at 115/230V)
8
Efficiency (Typ)
9
Inrush current
10
Hold-up time
11
Maximum line regulation
12
Max load regulation
13
Output Ripple and noise P-P
14
Temperature stability
15
Temperature coefficient
16
Remote sensing
17
Parallel operation
18
Series operation
19
Over current protection
20
Over voltage protection
21
Over temperature protection
22
Remote On/Off control
23
DC OK signal
24
Over-Temp. warning
25
AC fail signal
26
Auxiliary power supply
27
Vout voltage trimming
28
Front panel indicator
29
I²C Interface
30
Operating temperature
31
Storage temperature
32
Operating humidity
33
Storage humidity
34
Cooling
3S
Vibration
36
Shock
37
Conducted emission
38
Radiated emission
39
Applicable safety standards
40
Withstand voltage
41
Isolation resistance
42
Leakage current
43
Weight (Typ)
44
Size (W*H*D)
45
Notes:
*1: For cases where conformance to various safety standards (UL, EN etc.) is required.
to be described as 100-240Vac (50/60Hz).
*2: At 100/200Vac, rated load and 25°C ambient temperature.
*3: Not applicable for the noise filter inrush current less than 0.2mS.
*4: Measured with JEITA RC-9131A 1:1 probe, 20MHz B.W.
*5: From 85-132Vac or 170-265Vac, constant load.
*6: From No-load to Rated load, constant input voltage. Measured at the sensing point in Remote sense.
*7: Remote sensing can compensate up to 1V drop on each load wire.
*8: Inverter shut down method. Reset by AC voltage recycle or by On/Off control.
*9: Derate Maximum output power by 10% for input voltage less than 95VRMS
*10 RFE1000 series considered as professional equipment and not intended for sale to general public.
Model
RFE1000 -24
V/I
V1 (V)
24
V2 (V)
29
I1 (A)
33
I2 (A)
40
RFE1000-24
V
V
V
A
(*9)
W
(*1)
-
A
-
(*2)
%
(*3)
A
mS
20mS typical at 100Vac input, rated output voltage and less than 80% of rated load
(*5)
-
(*6)
-
(*4)
mV
-
0.1 % of rated Vout for 8hrs after 30mln warm-up. Constant line. load and temperature.
PPM/°C
(*7)
-
Possible. Refer to Instruction Manual.
-
Possible. Refer to Instruction Manual.
-
Possible. Refer to Instruction Manual.
-
105--125% of maximum output current. Refer to Fig. 1
(*8)
V
-
Inverter shut down method, automatic recovery.
-
By electrical signal or dry contact. ON: 0~0.6V or short. OFF: 2~15V or open.
-
Open collector signal. On when Vout>80+/-5% rated output. Max.sink current: 10mA
-
Open collector signal. Refer to Instruction Manual
-
Open collector signal. Refer to Instruction Manual
-
11.2~12.5VDC. 0.25A Maximum output current.
-
Possible, via Vout Trim Potentiometer on PCB. Refer to Instruction Manual.
-
DC OK. Refer to Instruction Manual.
-
No
0~50°C: 100% load.
-
+50°C to +60°C: Derate 2%/°C of load
+60°C to +70°C: Derate 2.5%/°C of load
-
-30....85°C
-
10-90% RH, no condensation.
-
10-95% RH, no condensation.
-
By internal Fans. Variable speed control.
-
Built to meet ETS 300 019
-
Built to meet ETS 300 019
-
Built to meet EN55032B, FCC part 15J-B, VCCI-B
(*10)
-
Built to meet EN55032B, FCC part 15J-B, VCCI-B
-
IEC 62368-1 UL62368-1 CSA22.2 No.62368-1 EN62368-1.
Input-Output:
3000Vrms, 1min.
Input-Ground:
-
2000Vrms, 1min.
Output-Ground:
500Vrms, 1min.
-
More than 100Mohm at 25°C and 70% RH. Output-Ground: 500Vdc
mA
Less Than 1.1 mA at 230Vac
Kg
2.0
-
127x41 x305 mm. Refer to Outline Drawing.
RFE1000 -32
RFE1000 -48
32
48
38.4
58
26
17.25
31
21
RFE1000-32
24
32
24+/-1%
32+/-1%
21.5-29
28.8-38.4
40
31
960
992
85~265Vac continuous, 47~63Hz, Single phase
12.0/6.0
>0.98 at maximum output power
86/88%
86/88%
Less than 40A
0.40%
0.80%
200
250
200
31~34
41.5~45.5
Vout (V)
V2
V1
Fig. 1: Rated output current vs output voltage
13
RFE1000-48
48
48+/-1%
43-58
21
1008
87/89%
300
62~66
Iout (A)
I1
I2

Publicité

loading

Ce manuel est également adapté pour:

Rfe1000-32Rfe1000-48