Problem
Possible Cause
Cable twisting or cable
Obstruction in pool
coils up
Gets stuck on main drain cover
Excess cable in the pool
Cleaner is moving in
Dirt stuck in moving parts
circles
Tracks worn due to extended use
Power supply positioned incorrectly
Algae in pool
Cleaner does not
Power supply positioned incorrectly
reach all areas of the
pool
Cleaner does not climb walls
Algae on pool walls and floor
Pool filter and pump is on
Cleaner does not
Cleaner is too heavy
climb walls
Algae on walls
Water temperature too low and/or too
high
Brushes are worn
Debris caught around impeller
Cleaner is too light from trapped air
Unsuitable pH level
Motor not working
Impeller blocked
Drive system blocked
Electrical problem - motor unit,
communication cable, or power supply
Cleaner will not sink
Air caught in trapped in cleaner
Power supply or power
Not plugged in properly or main
supply switch light is
socket is damaged
not working

TROUBLESHOOTING

PROWLER™ 930 Robotic Inground Pool Cleaner Installation and User' s Guide
Corrective Action
Remove obstruction in pool.
Turn off filter and install main drain cover ring.
Straighten cable and lay in sun periodically.
Remove excess cable from pool.
Remove dirt from moving parts.
Contact your dealer. Replace tracks.
Place power supply in a position so that the
cleaner can reach all walls.
Correct pool and water conditions.
Place power supply in a position so that the
cleaner can reach all walls.
Check reasons for not climbing walls below.
Brush pool walls and floor.
Turn off pool filter and pump and run another
cleaning cycle.
Clean and wash cartridge.
Brush walls.
Ideal water temperature between 6-35°C
(43-95°F).
Replace brushes - contact your dealer.
Clean impeller (see page 8).
Turn cleaner upside down under water to
remove trapped air.
Check pH level - should be between 7.4 - 7.8;
minimum level of 7.2.
Clean impeller (see page 8).
Clean tracks and wheels.
Consult with your dealer or service center.
Turn cleaner upside down under water to
remove trapped air. Wash the cartridge.
Remove calcium deposits or other chemical
sediments.
Open inlet flap in the bottom lid to remove dirt
and/or trapped air.
Reconnect and check main power supply.
13