-
The upper ventilation shaft can either be positioned directly
above the appliance with an optional ventilation grille
Fig. 4 (C) , close to the ceiling above the unit Fig. 4 (D) or as
an air outlet opening in a false ceiling
8 Changing over door hinges
NOTICE
Risk of damage due to condensation and colliding doors!
If you are installing V-Zug Side-by-Side (SBS) appliances
next to each other:
u Install the appliances so that the doors open outwards.
Switch the door hinges, if necessary.
CAUTION
Risk of injury if soft stop contracts!
u Carefully remove the soft stop mechanism.
CAUTION
Risk of injury if hinges fold!
u Leave hinges open.
WARNING
Risk of injury due to the door dropping out!
If the fastening parts are not screwed into place firmly enough,
the door may drop out. This may lead to severe injuries. What is
more, the door may not close and therefore the appliance may
fail to cool properly.
u Screw the hinges and the ball journal of the soft stop mecha-
nism firmly into place, with 4 Nm.
u Screw the holder of the soft stop mechanism firmly into
place, with at least 3 Nm.
u Check all of the screws and retighten if necessary.
Note
The door hinges can only be changed over if there is sufficient
space towards the top to pull out the hinge mounting bracket
and to mount it again on the other side. This is generally not the
case after installation in the recess.
u Change the hinges over before the appliance is installed in
the recess.
There is a risk of injury during this stage! Please
observe the safety instructions!
The instructions apply to several models. Only carry
out this step if it is relevant for your appliance.
* Depending on model and options
u While changing over the door hinges, observe the safety
instructions above and also the information in the symbols
key.
Change the hinges over as shown at the end
of the book.
Fig. 4
9 Water connection*
Fig. 4 (E) .
Danger of electric shock!
u Disconnect the appliance by unplugging it before you
connect it to the water line.
u Shut off the water supply before you connect the water feed
lines of the IceMaker.
u The connection to the drinking water system may be carried
out only by a qualified gas fitter and plumber.
Risk of poisoning!
u The water quality has to comply with the drinking water ordi-
nance of the respective country (e.g. 98/8
u Connect to the drinking water supply only.
u The IceMaker serves exclusively for making ice cubes in
household quantities and has to be operated with water suit-
able for the purpose.
Fig. 5
- The water pressure must be between 0.15 MPa and
0.6 MPa (1.5 bar - 6 bar).
- Water must be supplied to the appliance through a cold
water pipe that complies with hygiene standards and can
withstand the operating pressure.
Use the stainless steel hose supplied (Length 1.5 m) Do not
reuse old hoses. A 3 m hose is available as an optional
extra. This must be professionally installed.
A filter with a seal is located in the hose connector.
- A stopcock must be placed between the hose line and the
domestic water connection to cut off the water supply, if
necessary.
- All devices and equipment used to supply water must
comply with the regulations in force in the respective
country.
- Do not damage or kink the water supply line during installa-
tion.
Changing over door hinges
Choose between the alternatives given.
Loosen the screws only, do not undo them all the way.
Check the screws and tighten if necessary.
WARNING
WARNING
23