3. Terminal Connection Method
Please pay extra attention to the wiring. Incorrect connection may cause damage the power supply.
 When connecting input and output wiring, and CN1, input AC-Line should be OFF.
 The output load line and input line shall be separated and twisted to improve noise immunity.
 Connect FG terminal to ground terminal of the equipment.
 Remote ON/OFF control lines shall be twisted or use shielded wire.
 Output current for each terminal screw shall be less than 30A.
GWS250
 Basic Connection
Connect "CNT+" terminal to "CNT-" terminal
with the attached connector.
 ON/OFF control required
"CNT-" terminal is ground for "CNT+" terminal.
 DC_OK output signal required
Open collector method shown below shall be used
"COM" terminal is ground for "DC_OK" terminal.
 PV control required
Inject external voltage between 3~6V
"COM" terminal is ground for "PV" terminal.