INSTRUCTIONS FOR USE
ISTRUZIONI PER L'USO
AIR HYDRAULIC JACK USE AND CARE
• Place the jack so that the load is centred over it, at such gripping points as stated by the vehicle
manufacturer.
• If any extensions are needed, only use those supplied by the manufacturer with the jack. Do not use
the extensions without the plate. Do not use more than two extensions.
• Do not force the pressure relief valve that has the guarantee seal.
• Do not leave any pressure in the jack at end of stroke when there is no load.
• Before lowering the load, check that the handle is in the horizontal position.
• Store the jack in a suitable place when not in use.
• It is absolutely forbidden to make any structural changes to the jack, as these might affect its safety
characteristics.
PERSONAL PROTECTIVE EQUIPMENT TO WEAR WHILE USING AIR HYDRAULIC JACK
Failure to observe the following warnings may result in physical injury and/or disease.
ALWAYS WEAR SAFETY FOOTWEAR WITH PROTECTIVE TOE CAPS
ALWAYS WEAR MECHANICALLY RESISTANT PROTECTIVE GLOVES
The above-mentioned personal protective equipment refers to the use of the jack in normal
working environments. If any hazardous situations are shown following specific surveys,
it must be supplemented with such equipment as described in the risk assessment
document, in compliance with current standards concerning safety in the workplace.
TECHNICAL DATA
MAXIMUM CAPACITY
POWER SUPPLY PRESSURE
MAXIMUM AIR CONSUMPTION
AIR INLET
MINIMUM INTERNAL HOSE SIZE (ø)
MAXIMUM STROKE
MINIMUM HEIGHT
NUMBER OF PISTONS
PISTONS STROKE
OPERATING TEMPERATURE
WEIGHT
SOUND PRESSURE LEVEL
ASSEMBLY
Take the handle, the jack and the extensions out of the cardboard box. Unscrew both nuts from inside
the frame. (pict.10.) Undo screw from the frame and remove parts making sure that they are kept assembled.
Fit in the handle (the air distributor must be turned towards the pistons), with the coupling in the groove; fit the
previously removed parts into the hole of the handle; drive in the screw and tighten it with the nut.
Connect both air pipes coming out of the handle into the quick couplings of the frame, according to such
colours as shown in the sticker on the frame. Connect the jack to the compressed air system through the
quick coupling on top of the manual lifting/lowering control of the jack.
15 - 30 - 60t
8.0 ÷ 10 bar
600 nl/min
1/4" GAS, cone-shaped
6 mm
135 mm
120 mm
3
40 – 45 – 50 mm
-20 °C ÷ +50 °C
50 kg
60 dBA