Maintenance & service
o Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in
which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture's
optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days
There is no replaceable parts inside. DO NOT OPEN THE FIXTURE
o Troubleshooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
The fixture does not work, no light
o
Check the connection of power and main fuse.
o
Measure the mains voltage on the main connector.
Not responding to DMX controller
o
DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
o
If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
o
If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous
one.
o
Try to use another DMX controller.
o
Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to
DMX interface circuit.
Some fixtures don't respond to the easy controller
o
You may have a break in the DMX cabling.
No response to the sound
o
Make sure the fixture does not receive DMX signal.
o
Check microphone to see if it is good by tapping the microphone.
No light out
o
Please check if Red Emergency Button is up or down
Technical Specifications
Model:
Source:
Voltage:
Power consumption:
Outside size and N.W.:
EN60825-1:2014, application of the European Directives:
Directive LVD n°2014/35/EU
Directive RoHS n°2011/65/EU
Directive EMC n°2014/30/EU
M3000 User Manual Ver. 1.00
M3000
Class 4 LASER light
230v/50Hz
100 W max
/ 3.2kg
138*230*126mm
Page 19