• Recommended precautions
• Recommended precautions
Before unpacking the unit, check the outside of the package;
if you fi nd that the impact indicator is red, or the carton dama-
ged, accept the delivery on the condition of your inspection
of the unit.
The packaging frame is wood treated with ISPM-15 fumigation.
Treatment is certifi ed by the code stamped on the wood fra-
me. The packaging is recyclable, if not reused, dispose of it in
accordance with current regulations. Remove the screws that
secure the wood panels together, possibly using a pneumatic
screwdriver; start with the top panel. The unit is anchored to a
pallet. The drawing of the suction unit is under the address and
includes machine dimensions and weight. Keep the stoppers
that close all the external/internal communication points, so
that you may use them when moving the suction unit.
Only experienced personnel with the right tools must be allo-
wed to install the unit. The suction unit must be placed in a cle-
an area, away from sources of heat, humidity and dust. When
installing outside: balconies, porches and gardens, ensure that
the machine is sheltered from rain, spraying, humidity, frost
and direct exposure to sunlight.
The temperature in the plant room must not drop below +5°C
nor exceed +35°C.
If ventilation or air conditioning is needed in the plant room,
the ventilation or air conditioning system should be designed
by a thermal engineer. Access to the plant room must not be
allowed to patients or casual visitors. If a plant room is not
available, the machines must be protected with a cover that
is not easily removed. Provide protections and danger signs
to prevent accidental contact because of electrocution hazard
and for the (remote but possible) event of fi re, explosion, lea-
kage of contaminated liquids and air. Use only covers (for in-
door or outdoor use) designed and made by the manufacturer.
The manufacturer shall not be liable for machines protected
with cases made by other companies. Cover design requires
testing with temperature and functionality checks, measured
over time, with heat sensors and instruments for control of fl ow
rate and head.
No fl ammable material should be stored in the plant room; en-
sure that there is no possibility of gas leaks in the room. Do not
connect damaged equipment to the power mains; do not use
extension cords, multiple sockets or plugs. Before connecting
the unit to power mains, ensure that the line conforms with
C.E.I. . 64-8 standards and that the thermal switch has a class
"A" or "B" differential in accordance with EN 61008-1.