Technical data
Type
Power supply
Nominal current
Nominal force
Nominal locking force
Service life
Duty cycle
Housing
Ingress protection
Temp. range
Emission sound pressure level
Nominal stroke length * **
Additional functions **
*Adjustable with PLP 1
Running speed and forces
All forces + approx. 20 % switch-off reserve (temporary)
Closing edge protection
In the "CLOSE" direction the drive has an active
protection for the main closing edge. If there is an
overload in the closing ranges 3 and 2, the drive runs
"OPEN" for 20 seconds, then "CLOSE" again. If
closing is not possible after three attempts, the drive
remains in this position.
In addition, the drive is equipped with passive
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing edges.
Danger of crushing hands and fingers!
6/16
VCD 203
VCD 203
24 V DC / ± 20 %
0,35 A
200 N
approx. 2000 N (Excluding bracket)
>20 000 double strokes
30 % (With cycle time 10 minutes)
Zinc-diecasting, powdercoated
IP 30
0 ... +60 °C
LpA ≤ 46 dB(A)
/
250 mm
Closing edge protection activated (3 stroke repeatings);
Locking relief activated
** Programmable with PLP 1 and SCS
English
99.826.05 1.2/02/20