Specifications - Mitsubishi Electric CITY MULTI PUHY-P72TNU-A-B Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Specifications

(1) TNU models
Model
Sound pressure level
*4 *5
External static pressure
Total capacity
Indoor unit
Model
Quantity
Operation
Outdoor D.B.
temperature
Indoor
W.B.
(Cooling)
Operation
Outdoor W.B.
temperature
Indoor
D.B.
(Heating)
Model
Sound pressure level
*4 *5
External static pressure
Total capacity
Indoor unit
Model
Quantity
Operation
Outdoor D.B.
temperature
Indoor
W.B.
(Cooling)
Operation
Outdoor W.B.
temperature
Indoor
D.B.
(Heating)
Model
Sound pressure level
*4 *5
External static pressure
Total capacity
Indoor unit
Model
Quantity
Operation
Outdoor D.B.
temperature
Indoor
W.B.
(Cooling)
Operation
Outdoor W.B.
temperature
Indoor
D.B.
(Heating)
Model
Sound pressure level
*4 *5
External static pressure
Total capacity
Indoor unit
Model
Quantity
Operation
Outdoor D.B.
temperature
Indoor
W.B.
(Cooling)
Operation
Outdoor W.B.
temperature
Indoor
D.B.
(Heating)
*1 The maximum total capacity of indoor units operating simultaneously is 130%.
*2 To enable the high static pressure setting, set the dipswitch on the main board as follows.
SW6-5: ON
SW6-4: ON
80 Pa
SW6-4: OFF
30 Pa
*3 When applying product below -20.0°C (-4.0°F), consult your design engineer for cold climate application best practices, including the use of a
backup source for heating.
*4 Cooling mode
*5 The sound pressure level shown above indicates A-weighted sound pressure level. Although the sound pressure level in JIS has been changed
to the sound power level (PWL), the value shown above indicates the sound pressure level measured by the conventional method for reference
purpose.
WT09452X01
PUHY-P72TNU-A(-BS)
PUHY-P96TNU-A(-BS)
55.0 dB <A>
56.5 dB <A>
0 Pa*
2
50% to 130%*
1
05 to 96
1 to 15
1 to 20
-5.0°C to +52.0°C (+23.0°F to +125.6°F)
+15.0°C to +24.0°C (+59.0°F to +75.0°F)
-25.0°C to +15.5°C (-13.0°F to +60.0°F)*
+15.0°C to +27.0°C (+59.0°F to +81.0°F)
PUHY-P120TNU-A(-BS)
PUHY-P144TNU-A(-BS)
60.0 dB <A>
62.5 dB <A>
1 to 26
1 to 31
-5.0°C to +52.0°C (+23.0°F to +125.6°F)
+15.0°C to +24.0°C (+59.0°F to +75.0°F)
-25.0°C to +15.5°C (-13.0°F to +60.0°F)*
+15.0°C to +27.0°C (+59.0°F to +81.0°F)
PUHY-P216TSNU-A(-BS)
PUHY-P240TSNU-A(-BS)
62.0 dB <A>
63.5 dB <A>
2 to 46
2 to 50
PUHY-P336TSNU-A(-BS)
PUHY-P360TSNU-A(-BS)
64.0 dB <A>
65.0 dB <A>
2 to 50
2 to 50
SW6-5: OFF
60 Pa
0 Pa
3
PUHY-P168TNU-A(-BS)
60.5 dB <A>
0 Pa*
2
50% to 130%*
1
05 to 96
1 to 36
3
PUHY-P264TSNU-A(-BS)
61.0 dB <A>
0 Pa*
2
50% to 130%*
1
05 to 96
2 to 50
-5.0°C to +52.0°C (+23.0°F to +125.6°F)
+15.0°C to +24.0°C (+59.0°F to +75.0°F)
-25.0°C to +15.5°C (-13.0°F to +60.0°F)*
+15.0°C to +27.0°C (+59.0°F to +81.0°F)
PUHY-P384TSNU-A(-BS)
66.0 dB <A>
0 Pa*
2
50% to 130%*
1
05 to 96
2 to 50
-5.0°C to +52.0°C (+23.0°F to +125.6°F)
+15.0°C to +24.0°C (+59.0°F to +75.0°F)
-25.0°C to +15.5°C (-13.0°F to +60.0°F)*
+15.0°C to +27.0°C (+59.0°F to +81.0°F)
GB-11
PUHY-P192TSNU-A(-BS)
60.0 dB <A>
1 to 41
PUHY-P288TSNU-A(-BS)
PUHY-P312TSNU-A(-BS)
62.5 dB <A>
64.0 dB <A>
2 to 50
2 to 50
3
PUHY-P408TSNU-A(-BS)
PUHY-P432TSNU-A(-BS)
67.0 dB <A>
67.5 dB <A>
3 to 50
3 to 50
3

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

City multi puhy-p96tnu-a-bsCity multi puhy-p120tnu-a-bsCity multi puhy-p144tnu-a-bsCity multi puhy-p168tnu-a-bsCity multi puhy-p192tsnu-a-bsCity multi puhy-p216tsnu-a-bs ... Afficher tout

Table des Matières