Vermiculite plates
Baffle plates
Sealing bands
If these parts need replacing, you may order them from your dealer - please refer to the Maintenance section.
4. Supply of combustion air (optional)
When a wood-burning stove is installed in a room, the air supply requirements change. Air may be supplied indirectly via a
valve in the outer wall or via an external canal by connecting a connecting piece to the bottom section of the stove. The
connecting piece o.d. is Ø 100mm. The hot parts of the canal should be insulated against condensation, e.g. with 25mm
mineral wool with a moisture barrier on the outer face. Installing the stove, you should use joint filler to seal the pipe / wall
interface.
Through the bottom plate:
the plug in the bottom plate / back plate.

5. Adjustment of chimney connection.

On delivery, the stove has been prepared for a top outlet but may be amended to use a rear outlet as follows:
Use a hammer and/or screwdriver to remove the plug in the back plate
Through the back plate:
Loosen the 2 bolts securing the rear outlet plug
Loosen the 2 bolts securing the flue collar
Switch the flue collar and the rear outlet plug
Insert the top outlet cast iron plug.
Use a hammer and/or
screwdriver to remove