Emptying the ash pan
Open the door and remove the ash pan from a cold stove. Use a closed steel
container to store the ash and/or transport it and discard it in a secure manner.
Note: embers may be hidden in the ash for several days.
8. The Clean Air Act and Smoke Control Areas
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any
fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised
fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the
controls which generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise
smokeless fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales
this power rests with Ministers in the devolved administrations for those countries. Separate legislation, the
Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement that fuels
burnt or obtained for use in smoke control areas have been "authorised" in Regulations and that appliances
used to burn solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order
made and signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and
supervision of smoke control areas and you can contact them for details of Clean Air Act requirements"
Bella UK, Bella w/o sideglass UK, Bella High UK and Bella High w/o sideglass UK has been recommended as suitable for
use in smoke control areas when burning wood logs.
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur.
Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a
reasonable period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
The following text may be required depending on appliance operation and instructions:
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left
open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated
with air controls or appliance dampers left open except as directed in the instructions.
Air regulation
The stoves air regulation is retrofitted with a kit from the factory, to meet the demands for smoke controlled areas.